Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0170005 Power Module Input Is Abnormal

0xF0170005 Power Module Input Is Abnormal

Description

The input to a power module is abnormal.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF0170005

Alarm

Major

Yes

Impact on the System

  • The storage system reliability decreases.
  • The storage system may not work correctly.

Possible Causes

  • Power cables are not securely connected or damaged.
  • The input voltage is too high or too low.
  • The power module is faulty.

Procedure

  1. Check the power cables connected to the power module.

    1. If any power cable is not securely connected, reinsert the power cable. If the alarm persists=> 1.2
    2. Replace the power cable. If the alarm persists=> Step2.

  1. Check whether the input power voltage is too high or too low.

    1. If yes, stabilize the input power voltage. If the alarm persists=> Step3.
    2. If no=> Step3.

  2. Check whether alarms on power module faults are generated.

    1. If yes, replace the faulty power modules. If the alarm persists=> Step4.
    2. If no=> Step4.

  3. Collect related information and contact technical support engineers.