Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF01050024 Switch Port Negotiated Rate Is Smaller Than The Allowed Maximum Rate

0xF01050024 Switch Port Negotiated Rate Is Smaller Than The Allowed Maximum Rate

Description

The negotiated rate of a switch port is smaller than the allowed maximum.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF01050024

Alarm

Warning

Yes

Impact on the System

The interface module where the port resides cannot provide services.

Possible Causes

  • The rate supported by the peer port is smaller than that of the port.
  • The cable to the port is loose or damaged.
  • A port component is faulty.

Procedure

  1. Check whether the rate of the port's peer port is smaller than that of the port.

    1. If no=> Step2.
    2. If yes, no further action is required.

  1. Check cable connections.

    1. Connect the cable correctly to the port. If the alarm persists=> 2.2.
    2. Replace the cable. If the alarm persists=> Step3.

  2. Replace the modules where the port and its peer port reside. If the alarm persists=> Step4.
  3. Collect related information and contact technical support engineers.