Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF000A0103 SATA Disks And Non-SATA Disks Mixed

0xF000A0103 SATA Disks And Non-SATA Disks Mixed

Description

SATA disks and non-SATA disks are mixed.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF000A0103

Alarm

Warning

Yes

Impact on the System

The performance of SATA disks may be affected.

Possible Causes

SATA disks and non-SATA disks are mixed in the disk enclosures connected to the same SAS port of controller.

Procedure

  1. Rectify the problem based on maintenance case Handling the Alarm of Using both SATA and Non-SATA Disks on a SAS Port. If the alarm persists=> Step2.
  2. Collect related information and contact technical support engineers.
Translation
Download