Event Reference for File

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00280124 The Split Task Of A Clone File System Terminated Unexpectedly

0xF00280124 The Split Task Of A Clone File System Terminated Unexpectedly

Description

The split task of a clone file system terminates unexpectedly.

Applicable Model

Applicable to all models.

Attribute

ID

Event Type

Event Level

Automatically Cleared

0xF00280124

Alarm

Warning

Yes

Impact on the System

N/A

Possible Causes

  • The storage pool has fault or the capacity is insufficient.
  • The remaining capacity of the clone file system is insufficient.
  • The parent file system or the clone file system is abnormal.

Procedure

  1. Check whether an alarm exists in the storage pool where the clone file system resides.

    1. If yes, handle with related suggestions. If the alarm persists=> Step2.
    2. If no=> Step2.

  2. Check whether an alarm exists in the parent file system, clone file system, or in their disk domain.

    1. If yes, handle with related suggestions. If the alarm persists=> Step3.
    2. If no=> Step3.

  3. Collect related information and contact technical support engineers.