Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change HA_parameter

change HA_parameter

Function

Change HA parameter.

Format

change HA_parameter [management_floating_ip=?] [quorum_gateway=?]

Parameters

Parameter

Description

Value

management_floating_ip=?

Floating ip, which is Used by a maintenance terminal or a third-party system to log in to the eBackup system.

The value must be a legally available IP address.

quorum_gateway=?

Quorum_gateway, which is used to determine whether to trigger a primary/standby switchover. One to three quorum gateways can be configured.

The value must be a legally available gateway address.

Views

management

Level

Super administrator

Usage Guidelines

None

Example

Change HA parameter management_floating_ip to be 192.168.21.24.


management:/>change HA_parameter management_floating_ip=192.168.21.24 
Command send successfully. 

System Response

None