Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Performing a Health Check

Performing a Health Check

Run the following command to perform a health check:

./dswareTool.sh --op healthCheck -nodeIp nodeIp1,nodeIp2,... -nodeType nodeType -items item1,item2,... -nodeUserName(optional) nodeUserName

Parameter

Description

./dswareTool.sh

Specifies an executable program for the tool.

--op healthCheck

Performs a health check.

-nodeIp nodeIp1,nodeIp2,...

Specifies the IP addresses of the nodes to be checked. Multiple IP addresses are separated using commas (,).

-nodeType nodeType

Specifies the type of the node to be checked. The value can be FSM, FSA, or Cluster.

-items item1,item2,...

Specifies the health check items. Multiple items are separated using commas (,).

-nodeUserName(optional) nodeUserName

Specifies the user name for logging in to the standby FSM node. This parameter is mandatory only when a standby FSM node health check is performed.

An IPv4 example is provided as follows:

Performing the FSA node health check

dsware@KD182249181115:/opt/dsware/client/bin> sh dswareTool.sh --op healthCheck -nodeIp 192.168.81.21 -nodeType FSA -items 4100
[Fri Mar 31 14:43:32 CST 2017] DswareTool operation start.
Operation finish successfully. Result Code:0
nodeIp:192.168.81.21

[Fri Mar 31 14:43:35 CST 2017] DswareTool operation end.

Performing the standby FSM node health check

dsware@KD182249181115:/opt/dsware/client/bin> sh dswareTool.sh --op healthCheck -nodeIp 192.168.4.2 -nodeType FSM -items 4100
[Fri Mar 31 14:42:11 CST 2017] DswareTool operation start.
Operation finish successfully. Result Code:0
nodeIp:192.168.4.2

[Fri Mar 31 14:42:15 CST 2017] DswareTool operation end.

Performing the cluster health check

dsware@KD182249181115:/opt/dsware/client/bin> sh dswareTool.sh --op healthCheck -nodeIp 192.168.4.2 -nodeType Cluster -items 4100
[Fri Mar 31 16:12:51 CST 2017] DswareTool operation start.
Operation finish successfully. Result Code:0
nodeIp:192.168.4.2
itemId-result-resultDetail:4100-0-The FusionStorage cluster is normal.  Active MDC IP address: 192.168.81.8  The storage cluster is normal.  The VBS cluster is normal.  Active VBS ID: 19  Active VBS IP address: 192.168.81.20

[Fri Mar 31 16:12:54 CST 2017] DswareTool operation end.

An IPv6 example is provided as follows:

Performing the FSA node health check

dsware@KD182249181115:/opt/dsware/client/bin> sh dswareTool.sh --op healthCheck -nodeIp 2016:8:40:160:c13:0:169:34 -nodeType FSA -items 4100
[Fri Mar 31 14:43:32 CST 2017] DswareTool operation start.
Operation finish successfully. Result Code:0
nodeIp:2016:8:40:160:c13:0:169:34

[Fri Mar 31 14:43:35 CST 2017] DswareTool operation end.

Performing the standby FSM node health check

dsware@KD182249181115:/opt/dsware/client/bin> sh dswareTool.sh --op healthCheck -nodeIp 2016:8:40:160:c13:0:169:34 -nodeType FSM -items 4100
[Fri Mar 31 14:42:11 CST 2017] DswareTool operation start.
Operation finish successfully. Result Code:0
nodeIp:2016:8:40:160:c13:0:169:34

[Fri Mar 31 14:42:15 CST 2017] DswareTool operation end.

Performing the cluster health check

dsware@KD182249181115:/opt/dsware/client/bin> sh dswareTool.sh --op healthCheck -nodeIp 2016:8:40:160:c13:0:169:34 -nodeType Cluster -items 4100
[Fri Mar 31 16:12:51 CST 2017] DswareTool operation start.
Operation finish successfully. Result Code:0
nodeIp:2016:8:40:160:c13:0:169:34
itemId-result-resultDetail:4100-0-The FusionStorage cluster is normal.  Active MDC IP address: 2016:8:40:160:c13:0:169:34  The storage cluster is normal.  The VBS cluster is normal.  Active VBS ID: 19  Active VBS IP address: 2016:8:40:160:c13:0:169:34

[Fri Mar 31 16:12:54 CST 2017] DswareTool operation end.
NOTE:
  1. Health check cannot be performed simultaneously on the FSM nodes, FSA nodes, or a cluster, that is, nodeType can be set only to FSM, FSA, or Cluster.
  2. The check result will be displayed on the screen, including the node IP address (nodeIp) and results of the check items (itemId-result-resultDetail).
  3. If the health check is performed on the cluster, nodeIp is determined by the deployment mode of the FSM node. If the FSM node is deployed in active/standby mode, nodeIp is the floating IP address. If the FSM node is deployed in standalone mode, nodeIp is the management IP address of the FSM node.

Translation
Download
Updated: 2019-07-12

Document ID: EDOC1100081411

Views: 4705

Downloads: 3

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next