No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FusionStorage 8.0.0 DSware Tool Command Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Forcibly Deleting a Disk

Forcibly Deleting a Disk

This operation is risky. You must confirm whether to continue to execute the command.

Run the following command to forcibly remove a faulty disk in the event of two points of failure:

./dswareTool.sh --op forceOutDisk -id poolId -slot slotNo -nodeMgrIp nodeMgrIp

Parameter

Description

./dswareTool.sh

Specifies an executable program for the tool.

--op forceOutDisk

Specifies the command for forcibly removing a disk.

-id poolId

Specifies the ID of the storage pool from which the faulty disk is to be forcibly removed, for example, 0.

-slot slotNo

Specifies the slot number of the disk to be forcibly removed, for example, 2.

-nodeMgrIp nodeMgrIp

Specifies the management IP address of the node where the faulty disk locates, for example, 172.21.36.21.

An IPv4 example is provided as follows:

[dsware@FSM01 bin]$ sh /opt/dsware/client/bin/dswareTool.sh --op forceOutDisk -id 0 -slot 1 -nodeMgrIp 10.90.211.32 
[Thu Aug 4 11:08:42 CST 2016] DswareTool operation start.
time task has started!
Enter User Name:admin
Enter Password :
Operation finish successfully. Result Code:0
[Thu Aug 4 11:08:52 CST 2016] DswareTool operation end.

An IPv6 example is provided as follows:

[dsware@FSM01 bin]$ sh /opt/dsware/client/bin/dswareTool.sh --op forceOutDisk -id 0 -slot 1 -nodeMgrIp 2016:8:40:160:c13:0:169:34 
[Thu Aug 4 11:08:42 CST 2016] DswareTool operation start.
time task has started!
Enter User Name:admin
Enter Password :
Operation finish successfully. Result Code:0
[Thu Aug 4 11:08:52 CST 2016] DswareTool operation end.