No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

FusionStorage 8.0.0 DSware Tool Command Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Adding a Storage Node

Adding a Storage Node

This operation is risky. You must confirm whether to continue to execute the command.

Run the following command to add a storage node:

./dswareTool.sh --op addStorageNode -poolId poolId -mediaType sas_disk/sata_disk/ssd_card/ssd_disk -cacheType nvdimm/ssd_card/ssd_disk/none/mem_sim -f pathname

Parameter

Description

./dswareTool.sh

Specifies an executable program for the tool.

--op addStorageNode

Adds a storage node.

-poolId poolId

Specifies the ID of the storage pool to be expanded, for example, poolId can be set to 0.

-mediaType sas_disk/sata_disk/ssd_card/ssd_disk

Specifies the main storage type. The value can be sas_disk/sata_disk/ssd_card/ssd_disk.

-cacheType nvdimm/ssd_card/ssd_disk/none/mem_sim

Specifies the cache type. The value can be nvdimm/ssd_card/ssd_disk/none/mem_sim.

-f pathname

Specifies the path for storing the file of the storage node to be added, for example, /opt/dsware/client/conf/dsware.xml.

An example is provided as follows:

dsware@FSM:/opt/dsware/client/bin> ./dswareTool.sh --op addStorageNode -poolId 0 -mediaType sas_disk -cacheType none -f /opt/dsware/client/conf/dsware.xml
This operation is high risk,please input y to continue:y
[Mon Oct 26 16:33:27 CST 2015] DswareTool operation start.
Operation finish successfully. Result Code:0
task id: 17
[Mon Oct 26 16:33:29 CST 2015] DswareTool operation end.
NOTE:

Modify the /opt/dsware/client/conf/dsware.xml configuration file based on the actual environment condition before running this command. A taskId value is displayed after the command is successfully ran. Then you can run the queryTaskInfo command to query the process of the node adding task.