Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Recovering From I/O Subhealth

Recovering From I/O Subhealth

Run the following command to recover from I/O subhealth.

./dswareTool.sh --op restoreSubhealthNode -nodeMgrIp ip

Parameter

Description

./dswareTool.sh

Specifies an executable program for the tool.

--op restoreSubhealthNode

Recovers the nodes from I/O Subhealth

-nodeMgrIp ip

Specifies a management IP address of the node which requires recovering from I/O subhealth.

An example is provided as follows:

dsware@FSM01:/opt/dsware/client/bin> ./dswareTool.sh --op restoreSubhealthNode -nodeMgrIp 192.168.2.166  
[Mon Jun 3 10:17:28 CST 2019] DswareTool operation start.  
Enter User Name:admin  
Enter Password :  
Operation finish successfully. Result Code:0  
[Mon Jun 3 10:17:50 CST 2019] DswareTool operation end.