Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Forcibly Replacing a Main Storage Disk

Forcibly Replacing a Main Storage Disk

This operation is risky. You must confirm whether to continue to execute the command.

Run the following command to forcibly replace the faulty main storage disk in the event of a single point of failure in the resource pool:

./dswareTool.sh --op forceReplaceSingleDisk -id poolId -slot slotNo -nodeMgrIp nodeMgrIp -ignoreMediaFault(optional) true/false(default)

Parameter

Description

./dswareTool.sh

Specifies an executable program for the tool.

--op forceReplaceSingleDisk

Forcibly replaces a main storage disk.

-id poolId

Specifies the ID of the storage pool.

-slot slotNo

Specifies the slot of the disk.

-nodeMgrIp nodeMgrIp

Specifies the IP address of the node.

-ignoreMediaFault(optional) true/false(default)

Specifies whether to ignore the faulty medium. The value can be true or false (default). This parameter is optional.

An IPv4 example is provided as follows:

dsware@SZX1000100896:/opt/dsware/client/bin> ./dswareTool.sh --op  forceReplaceSingleDisk -id 0  -slot 3 -nodeMgrIp 172.21.36.21
This operation is high risk,please input y to continue:y
[Thu Aug 4 10:07:03 CST 2016] DswareTool operation start.
Operation finish successfully. Result Code:0
[Thu Aug 4 10:07:06 CST 2016] DswareTool operation end.

An IPv6 example is provided as follows:

dsware@SZX1000100896:/opt/dsware/client/bin> ./dswareTool.sh --op  forceReplaceSingleDisk -id 0  -slot 3 -nodeMgrIp 2016:8:40:160:c13:0:169:32
This operation is high risk,please input y to continue:y
[Thu Aug 4 10:07:03 CST 2016] DswareTool operation start.
Operation finish successfully. Result Code:0
[Thu Aug 4 10:07:06 CST 2016] DswareTool operation end.