Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Forcibly Replacing the SSD or SSD Card

Forcibly Replacing the SSD or SSD Card

This operation is risky. You must confirm whether to continue to execute the command.

Run the following command to forcibly replace the SSD or SSD card in the event of a single point of failure in the resource pool:

./dswareTool.sh --op forceReplaceSSD -id poolId -oldEsn oldSSDEsn -newEsn newSSDEsn -nodeMgrIp nodeMgrIp -type main_storage/cache -ignoreMediaFault(optional) true/false(default)

Parameter

Description

./dswareTool.sh

Specifies an executable program for the tool.

--op forceReplaceSSD

Forcibly replaces the SSD or SSD card.

-id poolId

Specifies the ID of the storage pool.

-oldEsn oldSSDEsn

Specifies the ESN of the faulty SSD or SSD card.

-newEsn newSSDEsn

Specifies the ESN of the new SSD or SSD card.

-nodeMgrIp nodeMgrIp

Specifies the IP address of the node.

-type main_storage/cache

Specifies the role of the faulty SSD or SSD card. The value can be main_storage or cache.

-ignoreMediaFault(optional) true/false(default)

Specifies whether to ignore the faulty medium. The value can be true or false (default). This parameter is optional.

An IPv4 example is provided as follows:

dsware@FSM:/opt/dsware/client/bin> ./dswareTool.sh --op forceReplaceSSD -id 0 -oldEsn 022UUA10FS000049 -newEsn 022UUA10FS000049 -nodeMgrIp 192.168.60.146 -type cache 
This operation is high risk,please input y to continue:y 
[Fri Aug 21 00:28:39 CST 2015] DswareTool operation start.
Operation Finish successfully. Result Code:0
[Fri Aug 21 00:28:42 CST 2015] DswareTool operation end.

An IPv6 example is provided as follows:

dsware@FSM:/opt/dsware/client/bin> ./dswareTool.sh --op forceReplaceSSD -id 0 -oldEsn 022UUA10FS000049 -newEsn 022UUA10FS000049 -nodeMgrIp 2016:8:40:160:c13:0:169:32 -type cache 
This operation is high risk,please input y to continue:y 
[Fri Aug 21 00:28:39 CST 2015] DswareTool operation start.
Operation Finish successfully. Result Code:0
[Fri Aug 21 00:28:42 CST 2015] DswareTool operation end.