FusionStorage 8.0.0 DSware Tool Command Reference 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Switching the Active MDC or VBS Node

Switching the Active MDC or VBS Node

This operation is risky. You must confirm whether to continue to execute the command.

Run the following command to switch the active MDC or VBS node:

sh dswareTool.sh --op switchOverMasterNode -clusterType mdc/vbs -newMasterNodeIp(optional) ip -forceSwitchover(optional,only for mdc) true/false -lockCluster(optional,only for mdc) true/false

Parameter

Description

dswareTool.sh

Specifies an executable program for the tool.

--op switchOverMasterNode

Switches the active MDC or VBS node.

-clusterType mdc/vbs

Specifies the node type to be switched.

-newMasterNodeIp(optional) ip

Specifies the IP address of the new active node. This parameter is optional.

-forceSwitchover(optional,only for mdc) true/false

Specifies whether to forcibly switch the active node. This parameter is valid only for MDC nodes.

-lockCluster(optional,only for mdc) true/false

Specifies whether to lock the new active node. This parameter is valid only for MDC nodes.

If the MDC cluster is locked, ensure that the status of the VBS node to be configured as the active node is up.

An IPv4 example is provided as follows:

dsware@FSM01:/opt/dsware/client/bin> ./dswareTool.sh --op switchOverMasterNode -clusterType mdc -newMasterNodeIp 192.168.61.20 -forceSwitchover true -lockCluster true
This operation is high risk,please input y to continue:y
[Wed Nov 11 17:48:50 CST 2015] DswareTool operation start.
Operation finish successfully. Result Code:0
[Wed Nov 11 17:48:52 CST 2015] DswareTool operation end.

An IPv6 example is provided as follows:

dsware@FSM01:/opt/dsware/client/bin> ./dswareTool.sh --op switchOverMasterNode -clusterType mdc -newMasterNodeIp 2016:8:40:160:c13:0:169:32 -forceSwitchover true -lockCluster true
This operation is high risk,please input y to continue:y
[Wed Nov 11 17:48:50 CST 2015] DswareTool operation start.
Operation finish successfully. Result Code:0
[Wed Nov 11 17:48:52 CST 2015] DswareTool operation end.