Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Label Description

Label Description

Engineering Labels for Power Cables

This section describes the meaning of engineering labels attached to power cables.

Engineering Labels for AC Power Cables

  • Labels of this type are attached to AC power cables, including POWER, BGND, and PGND.
  • They are attached to both ends of AC power cables and only to one side of the sign plate of the cable tie.
  • The three core wires (220 V, working ground, and PGND) of a 220 V AC power cable are all covered with insulation sheaths. Therefore, each power cable requires a label only marked with AC and cabinet ID (the same for the 110 V cable and other cables).

Table A-75 describes the label that is attached to an AC power cable.

Table A-75 Content of the engineering label for an AC power cable

Label Content

Meaning

MN-AC

MN: cabinet ID or position number of power input (socket)

  • At the power socket side: indicates the cabinet ID.
  • At the loaded cabinet side: indicates the position number of power input (socket). A label must clearly identify the device position. If capable of being classified into rows and columns, positions of sockets can be marked by the same method as that marking labels at the loaded cabinet side. If incapable of being classified into rows and columns, positions of sockets must be specified to avoid confusion.

A label contains information about the position of the peer end of a cable (what TO: means). The label for the local end can be omitted, because the local end position has been known. Only information about peer end devices, such as a control cabinet or a cable distribution box, needs to be filled on the label.

Notice directions when attaching a label: The side of the cable tie, attached with a label, faces outside; characters on labels attached to cables in the same cabinet face the same direction, as shown in Figure A-97.

Figure A-97 Engineering labels for AC power cables

1. The label attached on a cable at the loaded cabinet side

Indicates the position of the PDC to which the cable is connected.

2. The label attached on a cable at the PDC side

Indicates the position of the loaded cabinet to which the cable is connected.

  • The label on the cable at the loaded cabinet side is marked A01-AC. It indicates that the power cable is connected to the power socket at row A and column 01 in the equipment room.
  • The label on the cable at the PDC side is marked B01-AC. It indicates that the power cable is connected to the loaded cabinet at row B and column 01 in the equipment room.

Engineering Labels for Network Cables

This section describes the meaning of engineering labels attached to network cables.

  • Applicable scope

    Shielded or unshielded network cables connected to network ports on the subrack board of a cabinet

  • Meaning of label content

    Table A-76 describes two sides of a label attached to a network cable.

Table A-76 Content of a network cable label

Label Content

Meaning

Example

MN-B-C-D

MN: cabinet ID

A01: indicates the first cabinet in row A.

B: subrack ID, numbered from bottom to top by two digits

01

C: physical board ID, numbered from top to bottom and from left to right by two digits

01

D: network port ID, numbered from top to bottom and from left to right

01

MN-Z

MN: cabinet ID

B02: indicates the second cabinet in row B.

Z: position number. Fill in the position number for an identifiable terminal device based on site requirements.

  • If a network cable is connected to a router in a cabinet, mark the router position by cabinet ID, subrack ID, and network port ID.
  • If a network cable is connected to a network management system (NMS), mark the position where the NMS is located.

B02-03

Figure A-98 Network cable label
  • A01-03- -05 indicates that one end of the network cable is connected to network port 05 on subrack 03 in the cabinet in row A, column 01 in the equipment room. No slot number is specified.
  • B02-03- -12 indicates that the other end of the network cable is connected to network port 12 on subrack 03 in the cabinet in row B, column 02 in the equipment room. No slot number is specified.

Engineering Labels for Optical Fibers

This section describes the meaning of engineering labels attached to optical fibers.

  • Applicable scope

    Optical fibers connected to optical connectors on boards of cabinet subracks or case devices

    Optical fiber labels are classified into two types based on connection modes:

    • Labels attached to optical fibers that connect two devices
    • Labels attached to optical fibers that connect devices to optical distribution frames (ODFs)
  • Label for an optical fiber between devices

    Table A-77 describes the label for an optical fiber connected between two devices.

    Table A-77 Label for an optical fiber between devices

    Label Content

    Description

    Example

    MN-B-C-D-R/T

    MN: cabinet ID

    If a local device and its peer device are located in different equipment rooms, device names can be used to specify their positions.

    A01: indicates the first cabinet in row A.

    B: subrack ID, numbered from bottom to top by two digits

    01

    C: physical board ID, numbered from top to bottom and from left to right by two digits

    05

    D: optical port ID, numbered from top to bottom and from left to right by two digits

    05

    R: optical receiving port

    T: optical transmitting port

    -

    Figure A-99 shows an example.

    Figure A-99 Label for an optical fiber between devices
    • A01-01- -01-R on one side of the label indicates that the local end of the optical fiber is connected to the 01 optical receiving port on the first subrack in the cabinet at row A and column 01 in the equipment room. No board ID is required.
    • G01-01- -01-T on the other side of the label indicates that the other end of the optical fiber is connected to the 01 optical transmitting port on the first subrack in the cabinet at row G and column 01 in the equipment room. No board ID is required.
  • Label for the optical fiber between a device and an ODF

    Table A-78 describes the label for the optical fiber connected between a device and an ODF.

    Table A-78 Label for the optical fiber between a device and an ODF

    Label Content

    Description

    Example

    MN-B-C-D-R/T

    MN: cabinet ID

    A01: indicates the first cabinet in row A.

    B: subrack ID, numbered from bottom to top by two digits

    01

    C: physical board ID, numbered from top to bottom and from left to right by two digits

    05

    D: optical port ID, numbered from top to bottom and from left to right by two digits

    05

    R: optical receiving port

    T: optical transmitting port

    -

    ODF-MN-B-C

    MN: row-and-column number for ODF

    • M: indicates a row of devices numbered A to Z from front to rear in the equipment room.
    • N: indicates a column of devices numbered 01 to 99 from left to right.

    G01: indicates the ODF at row G and column 01.

    B: row number of a terminal, ranked from 01 to 99

    01-01

    C: column number of a terminal, ranked from 01 to 99

    R: optical receiving port

    T: optical transmitting port

    -

    Figure A-100 shows an example.

    Figure A-100 Label for the optical fiber between a device and an ODF
    • ODF-G01-01-01-R on one side of the label indicates that one end of the optical fiber is connected to the optical receiving port at row 01 and column 01 on the ODF at row G and column 01 in the equipment room.
    • A01-01-05-05-R on the other side of the label indicates that the other end of the optical fiber is connected to the fifth optical receiving port on the fifth board of the first subrack of the cabinet at row A and column 01 in the equipment room.