FusionStorage 8.0.0 Block Storage Parts Replacement 04

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Replacing a Mounting Ear Plate of a 2288H V5 Node

Replacing a Mounting Ear Plate of a 2288H V5 Node

The procedures for replacing left and right mounting ear plates are the same. This section uses replacing the left mounting ear plate as an example.

Impact on the System

Before replacing the left or right mounting ear plate on a storage node, you must power off the node. This will adversely affect the services running on the node.

Prerequisites

A spare mounting ear plate is ready.

Precautions

Before replacing mounting ear plates, mark the connections of the cables.

Tools and Materials

  • Flat-head screwdrivers
  • Phillips screwdrivers
  • ESD gloves
  • ESD wrist straps
  • ESD bags
  • Labels

Procedure

  1. Log in to the primary management node as user dsware, and run the sh /opt/dsware/client/bin/dswareTool.sh --op setServerStorageMode -ip Management IP address of the faulty node -mode 1 command to switch to the maintenance mode. To run this command, enter the name and password of CLI super administrator account admin as prompted.
  2. Remove the faulty node from its cabinet, and remove its chassis cover. For details, see Basic Operations.
  3. Remove the air duct.

    Lift the air duct according to the signs on the air duct, as shown in Figure 17-1.
    Figure 17-1 Removing an air duct

  4. Remove the left mounting ear plate.

    1. Press and hold down the latch of the mounting ear signal cable, and remove the mounting ear plate signal cable in the arrow direction, as shown in step 1 in Figure 17-2.
      Figure 17-2 Removing the left mounting ear plate
    2. Unscrew the left mounting ear plate, as shown in step 2 in Figure 17-2.
    3. Remove the left mounting ear plate in the arrow direction and slowly pull the mounting ear plate signal cable out of the chassis along the chassis interior surface, as shown in step 3 in Figure 17-2.

  5. Place the removed mounting ear plate in an ESD bag.
  6. Take the spare mounting ear plate out of its ESD bag.
  7. Install the left mounting ear plate.

    1. Route the mounting ear plate signal cable through the chassis in the arrow direction, as shown in step 1 in Figure 17-3.
      Figure 17-3 Installing a left mounting ear plate
    2. Connect the mounting ear plate signal cable to the left mounting ear plate connector on the mainboard, as shown in step 2 in Figure 17-3.
    3. Install the mounting ear plate in the arrow direction, as shown in step 3 in Figure 17-3.
    4. Screw the left mounting ear plate, as shown in step 4 in Figure 17-3.

  8. Install the air duct.

    Align the positioning pins on the air duct with the fixing holes on the mainboard according to the instructions on the chassis, and vertically place the air duct downwards, as shown in Figure 17-4.
    Figure 17-4 Installing an air duct

  9. Put the node into the cabinet. For details, see Basic Operations.

    Log in to the primary management node as user dsware, and run the sh /opt/dsware/client/bin/dswareTool.sh --op setServerStorageMode -ip Management IP address of the faulty node -mode 0 command to switch to the normal mode. To run this command, enter the name and password of CLI super administrator account admin as prompted.

  10. Connect the storage node to the power sockets and peripheral devices according to the cable connection labels. Ensure that all cables are correctly connected and then power on the storage node. If the storage node is not powered on, press the power button on the front panel.
  11. Check the system status.

    On SmartKit, choose Home > Storage > Routine Maintenance > More > Inspection and check the system status.
    • If all inspection items pass the inspection, the inspection is successful.
    • If some inspection items fail, the inspection fails. Rectify the faults by taking recommended actions in the inspection reports. Perform inspection again after fault rectification. If the inspection still fails, contact Huawei technical support.

    For details, see the FusionStorage Block Storage Administrator Guide.

Follow-up Procedure

Label the replaced mounting ear plate to facilitate subsequent operations.