Opening the Maintenance Compartment Door
Precautions
- Do not open the panel of the solar inverter.
- Before opening the maintenance compartment door, ensure that no electrical connections are made for the solar inverter on the AC or DC side.
- If you need to open the maintenance compartment door in rainy or snowy days, take protective measures to prevent rain or snow from entering the maintenance compartment. If unavoidable, do not open the maintenance compartment door.
- Do not leave unused screws in the maintenance compartment.
Procedure
- Open the maintenance compartment door and install the support bar.Figure 5-7 Opening the maintenance compartment door
- Remove the accessories and keep them properly.Figure 5-8 Removing the accessories
- Select a crimping module according to the type of the AC output power cable.Figure 5-9 Select the crimping module
(A) Crimping module for multi-core cables of a 3-pin model
(B) Crimping module for single-core cables of a 3-pin model
(C) Crimping module for multi-core cables of 4-pin models
(D) Crimping module for single-core cables of 4-pin models
Follow-up Procedure
Use scissors to cut off the joints of the rubber rings to remove them. All rubber rings are removed in the same way.