Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Technical Specifications

Technical Specifications

Efficiency

Item

SUN2000-125KTL-M0

SUN2000-110KTL-M0

SUN2000-100KTL-M0

SUN2000-100KTL-M1

SUN2000-100KTL-INM0

Maximum efficiency

≥ 99.0%

≥ 98.6%

≥ 98.6%

≥ 98.6% (380 V/400 V) and ≥ 98.8% (480 V)

≥ 98.6% (415 V) and ≥ 98.8% (480 V)

Chinese efficiency

≥ 98.4%

≥ 98.2%

≥ 98.2%

-

-

European efficiency

-

-

-

≥ 98.4% (380 V/400 V) and ≥ 98.6% (480 V)

≥ 98.4% (415 V) and ≥ 98.6% (480 V)

Input

Item

SUN2000-125KTL-M0

SUN2000-110KTL-M0

SUN2000-100KTL-M0

SUN2000-100KTL-M1

SUN2000-100KTL-INM0

Maximum input power

140,300 W

123,500 W

112,200 W

112,200 W

112,200 W

Maximum input voltagea

1100 V

Operating voltage rangeb

200–1000 V

Minimum startup voltage

200 V

Full-load MPPT voltage range

625–850 V

540–800 V

540–800 V

540–800 V (380 V/400 V) and 625–850 V (480 V)

540–800 V (415 V)

625–850 V (480 V)

Rated input voltage

750 V

600 V

600 V

570 V (380 V), 600 V (400 V), and 720 V (480 V)

620 V (415 V) and 720 V (480 V)

Maximum input current (per MPPT)

26 A

Maximum input current (per PV string)

18 A

Maximum short-circuit current (per MPPT)

40 A

Maximum backfeed current to the PV array

0 A

Number of inputs

20

Number of MPP trackers

10

  • Note a: The maximum input voltage is the upper threshold of the DC voltage. If the input voltage exceeds the threshold, the solar inverter may be damaged.
  • Note b: If the input voltage is beyond the operating voltage range, the solar inverter cannot work properly.

Output

Item

SUN2000-125KTL-M0

SUN2000-110KTL-M0

SUN2000-100KTL-M0

SUN2000-100KTL-M1

SUN2000-100KTL-INM0

Rated active power

125 kW

110 kW

100 kW

100 kW

100 kW

Maximum apparent power

137.5 kVA

121 kVA

110 kVA

110 kVA

110 kVA

Maximum active power (cosφ = 1)

137.5 kW

121 kW

110 kW

110 kW

110 kW

Rated output voltagea (phase voltage/line voltage)

288 V/500 V, 3W + PE

220 V/380 V and 230 V/400 V, 3W + (N)b + PE

220 V/380 V and 230 V/400 V, 3W + (N)b + PE

220 V/380 V, 230 V/400 V, and 277 V/480 V, 3W + (N)b + PE

240 V/415 V and 277 V/480 V, 3W + (N)b + PE

Rated output current

144.4 A

167.2 A (380 V) and 158.8 A (400 V)

152.0 A (380 V) and 144.4 A (400 V)

152.0 A (380 V), 144.4 A (400 V), and 120.3 A (480 V)

139.2 A (415 V) and 120.3 A (480 V)

Adapted power grid frequency

50 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

50 Hz/60 Hz

Maximum output current

160.4 A

185.7 A (380 V) and 176.4 A (400 V)

168.8 A (380 V) and 160.4 A (400 V)

168.8 A (380 V), 160.4 A (400 V), and 133.7 A (480 V)

154.6 A (415 V), 133.7 A (480 V)

Power factor

0.8 leading and 0.8 lagging

Maximum total harmonic distortion (rated power)

< 3%

Note a: The rated output voltage is determined by Grid code, which can be set on the SUN2000 app, SmartLogger, or NMS.

Note b: You can determine whether to connect the neutral wire to the SUN2000-110KTL-M0, SUN2000-100KTL-M0, SUN2000-100KTL-M1, or SUN2000-100KTL-INM0 based on the application scenario. If no neutral wire is used, set Output mode to Three-phase three-wire. If the neutral wire is used, set the Output mode to Three-phase four-wire.

Protection

Item

SUN2000-125KTL-M0

SUN2000-110KTL-M0

SUN2000-100KTL-M0

SUN2000-100KTL-M1

SUN2000-100KTL-INM0

Input DC switch

Supported

Anti-islanding protection

Supported

Output overcurrent protection

Supported

Input reverse connection protection

Supported

PV string fault detection

Supported

DC surge protection

Type II

AC surge protection

Type II

Insulation resistance detection

Supported

Residue current monitoring unit (RCMU)

Supported

Overvoltage category

PV II/AC III

Display and Communication

Item

SUN2000-125KTL-M0

SUN2000-110KTL-M0

SUN2000-100KTL-M0

SUN2000-100KTL-M1

SUN2000-100KTL-INM0

Display

LED indicators, WLAN module + app, Bluetooth module + app, USB data cable + app

Communication

MBUS/RS485

Common Parameters

Item

SUN2000-125KTL-M0

SUN2000-110KTL-M0

SUN2000-100KTL-M0

SUN2000-100KTL-M1

SUN2000-100KTL-INM0

Dimensions (W x H x D)

1035 mm x 700 mm x 365 mm

Net weight

≤ 81 kg

≤ 90 kg

Operating temperature

–25°C to +60°C

Cooling mode

Intelligent air cooling

Highest operating altitude

4000 m

Relative humidity

0%–100% RH

Input terminal

Staubli MC4

Output terminal

Crimping module + OT/DT terminal

IP rating

IP66

Topology

Transformerless

Translation