PCIe Config
This section describes how to control PCIe ports on the PCIe Config screen.
The PCIe Config screen is used to configure the PCIe controller and link parameters as well as display status of each processor to control PCIe ports, such as enabling the PCIe port, selecting the connection rate, and configuring parameters such as the Max Payload Size parameter. Figure 1 or Figure 2 shows the PCIe Config screen. Table 4-14 describes the parameters on the screen.
Parameter |
Description |
Default Value |
---|---|---|
CPU 0 PCIe Configuration |
Sets the PCIe parameters of the PCIe port on CPU 0. |
N/A |
CPU 1 PCIe Configuration |
Sets the PCIe parameters of the PCIe port on CPU 1. NOTE:
TaiShan 200 servers (models 2180 and 5180) do not support this parameter. |
N/A |
CPU 2 PCIe Configuration |
Sets the PCIe parameters of the PCIe port on CPU 2. NOTE:
This parameter is supported by TaiShan 200 servers (model 2480) and TaiShan 200 Pro servers (model 2480). |
N/A |
CPU 3 PCIe Configuration |
Sets the PCIe parameters of the PCIe port on CPU 3. NOTE:
This parameter is supported only by TaiShan 200 servers (model 2480) and TaiShan 200 Pro servers (model 2480). |
N/A |
Support DPC |
Enables or disables the Deferred Procedure Call (DPC) function. The options are as follows:
|
Disable |
SRIOV |
Enables or disables Single Root Input/Output Virtualization (SRIOV). The options are as follows:
|
Enable |
PCIe DSM5# Mode |
Provides an advanced configuration and power interface (ACPI) to notify the OS kernel whether to reconfigure PCIe device resources. The options are as follows:
NOTE:
This parameter is not supported by TaiShan 200 servers (models XA320, XA320C, and 2480) or TaiShan 200 Pro servers (model 2480). |
BIOS Reserve |
PCIe Port Control Policy |
Specifies the PCIe port control policy. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Auto |
NVMe GEN4 Disk Workaround |
Enables or disables the performance optimization function of the NVMe Gen4 drive. Adjust the FC_Update parameter to improve the read performance of the NVMe Gen4 drive. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
SR-IOV System Page Size |
Specifies the SR-IOV system page size of the BIOS. When the BIOS allocates SR-IOV resources, it aligns pages based on the value of this field. It is recommended that the value of this field be the same as the value of the OS kernel page size. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
4K |
Slot1 BandWidth Splitting |
Splits the bandwidth of slot 1 on riser card 1. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
Slot2 BandWidth Splitting |
Splits the bandwidth of slot 2 on riser card 1. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
Slot3 BandWidth Splitting |
Splits the bandwidth of slot 3 on riser card 1. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
Slot4 BandWidth Splitting |
Splits the bandwidth of slot 1 on riser card 2. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
Slot5 BandWidth Splitting |
Splits the bandwidth of slot 2 on riser card 2. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
Slot6 BandWidth Splitting |
Splits the bandwidth of slot 3 on riser card 2. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
Support Bus Resource Adjustment |
Dynamically adjusts the number of PCIe buses for CPU 1. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Enabled |
Figure 4-22 shows the CPU 0 PCIe Configuration screen. Table 4-15 describes displayed parameters.
The screen varies according to the PCIe configuration.
Parameter |
Description |
---|---|
CPU 0 PCIe - Port 0 |
Sets the PCIe parameters of the PCIe port 0 on CPU 0. |
CPU 0 PCIe - Port 4 |
Sets the PCIe parameters of the PCIe port 4 on CPU 0. |
CPU 0 PCIe - Port 8 |
Sets the PCIe parameters of the PCIe port 8 on CPU 0. |
CPU 0 PCIe - Port 12 |
Sets the PCIe parameters of the PCIe port 12 on CPU 0. |
CPU 0 PCIe - Port 16 |
Sets the PCIe parameters of the PCIe port 16 on CPU 0. |
CPU 0 PCIe - Port 17 |
Sets the PCIe parameters of the PCIe port 17 on CPU 0. NOTE:
If the PCIe port is disabled, the KVM cannot work properly. You are advised to enable the PCIe port. |
CPU 0 PCIe - Port 18 |
Sets the PCIe parameters of the PCIe port 18 on CPU 0. |
The following uses CPU 0 PCIe - Port 0 as an example to describe the parameters that need to be set for enabling the PCIe port. Figure 4-23 shows the CPU 0 PCIe - Port 0 screen. Table 4-16 describes the parameters.
Parameter |
Description |
Default Value |
---|---|---|
PCI-E Port |
Sets whether to enable the PCIe port. The options are as follows:
|
Enable |
Link Speed |
Sets the link speed. The options are as follows:
|
Gen 4 (16 GT/s) |
PCI-E Port DeEmphasis |
Specifies the de-emphasis settings of the PCIe port. The options are as follows:
NOTE:
This parameter is available only when Link Speed is set to Gen 2 (5 GT/s). |
-6.0 dB NOTE:
For TaiShan 200 servers (model 2280, VE), the default value of this parameter is -3.5 dB. This parameter does not take effect when it is set to -6.0 dB. |
PCI-E Port Link Status |
Indicates the PCIe port link status. |
N/A |
PCI-E Port Link Max |
Indicates the maximum bandwidth of the PCIe port link. |
N/A |
PCI-E Port Link Speed |
Indicates the PCIe port link speed. NOTE:
This parameter is available when a PCIe device is connected. |
N/A |
Max Payload Size |
Sets the maximum payload size for a PCIe port. The options are as follows:
|
256B |
Figure 4-24 shows the PCIe Slot PXE Control screen. Table 4-17 describes the parameters.
- The screen varies according to the PCIe configuration.
- The PCIe Slot1 PXE Control to PCIe Slot8 PXE Control options are available only when External Network Card Boot is set to Enable.
- This parameter is supported only by BIOS V182 and later on TaiShan 200 servers (models 2280 and 5280).
Parameter |
Description |
Default Value |
---|---|---|
PCIe Slot1 PXE Control |
Indicates whether to enable PXE for PCIe slot 1. The options are as follows:
|
Enable |
PCIe Slot2 PXE Control |
Indicates whether to enable PXE for PCIe slot 2. The options are as follows:
|
Enable |
PCIe Slot3 PXE Control |
Indicates whether to enable PXE for PCIe slot 3. The options are as follows:
|
Enable |
PCIe Slot4 PXE Control |
Indicates whether to enable PXE for PCIe slot 4. The options are as follows:
|
Enable |
PCIe Slot5 PXE Control |
Indicates whether to enable PXE for PCIe slot 5. The options are as follows:
|
Enable |
PCIe Slot6 PXE Control |
Indicates whether to enable PXE for PCIe slot 6. The options are as follows:
|
Enable |
PCIe Slot7 PXE Control |
Indicates whether to enable PXE for PCIe slot 7. The options are as follows:
|
Enable |
PCIe Slot8 PXE Control |
Indicates whether to enable PXE for PCIe slot 8. The options are as follows:
|
Enable |