BBU Configuration
This parameter is supported by TaiShan 200 servers (models 2280, 2480, and 5280) and TaiShan 200 Pro servers (models 2480 and 2280).
This section describes how to configure the Battery Backup Unit (BBU) on the BBU Configuration screen.
Figure or Figure 4-62 shows the BBU Configuration screen. Table 4-46 describes the parameters on the screen.
The BBU Configuration screen varies according to the server or BIOS version. For details, see Table 4-46.
Parameter |
Description |
Default Value |
---|---|---|
Force Recovery |
Forcibly restores data on a hard drive to the memory. The options are as follows:
NOTE:
Only the BIOSs on the following servers support this parameter:
|
Disable |
Force recovery data from HDD to NvMem |
Forcibly restores data on a hard drive to the battery-protected memory. Select the parameter and press Enter. A confirmation dialog box is displayed. NOTE:
|
- |
Force Clear Data |
Forcibly clears backup memory data. |
- |
NV Size |
Sets the memory size for data backup. The options are as follows:
NOTE:
The options of this parameter vary according to the server. |
16G |
NV Location |
Sets the location of the backup memory. The options are as follows:
NOTE:
This parameter is supported only by BIOS V158, V137, and versions earlier than V137 on TaiShan 200 servers (models 2280, 5280, and 2480). |
All |
HDD Number |
Sets the number of hard drives to be backed up. The options are as follows:
NOTE:
|
2 |