Tools
The onsite technical personnel can select tools based on the site requirements.
Personal protective equipment
Safety helmet |
Goggles |
Dust mask |
Protective shoes |
Reflective vest |
ESD gloves |
Insulated gloves |
Protective gloves |
Antifreeze gloves |
Safety harness |
Safety belt |
- |
Hoisting and transport tools
Manual pallet truck |
Electric forklift |
Lifting sling and lifting eye |
Steel hoisting rope and lifting eye |
Lever |
- |
- |
- |
Hardware installation tools
Flat-head insulated torque screwdriver (M3/M4) |
Phillips insulated torque screwdriver (M4/M5/M6/M8) |
Insulated torque socket wrench (M6/M8/M10/M12) |
Open-end wrench (10 mm/13 mm/18 mm) |
Adjustable wrench (10"/15") |
Adjustable torque wrench |
Hammer drill |
Hammer drill bit (Φ22) |
Claw hammer |
Electric screwdriver |
Marker |
Step ladder |
Combination pliers |
Hacksaw |
Flashlight |
Thermometer |
Soft measuring tape |
Steel measuring tape |
Square |
- |
Pipe connection tools
Cutter |
Thread sealant/sealing tapea |
Thermal insulation foam sealant (sealing tape)b |
Welding torch |
Silver welding rod |
Oxygen cylinder |
Acetylene |
Nitrogen |
Hot melt device (for rigid pipes) |
Pipe bender |
- |
- |
a: The specifications of thread sealant/sealing tape are as follows:
b: Temperature resistance 85°C at least for thermal insulation foam sealant or sealing tape |
Cable Installation Tools
Wire strippers |
Needle-nose pliers |
Diagonal pliers |
Power cable crimping tool |
RJ45 crimping tool |
Insulation tape |
Heat shrink tubing |
Heat gun |
Cable tie |
- |
- |
- |
Commissioning tools
Vacuum pumpc |
Rubber hose (5 PCS)d |
Pressure gauge (2 PCS)d |
Reducing valvee |
Nitrogenf |
Electronic balance |
Multimeter |
Clamp meter |
Thermocouple temperature sensor |
- |
- |
- |
c: The flow rate of the vacuum pump should range from 2 L/s to 4 L/s. The absolute vacuum degree should be 60 Pa at most. d: The pressure gauges and rubber hoses must be dedicated for R410A. The measuring range of the pressure gauges must be at least 4.0 MPa, and the rubber hoses must withstand a pressure of at least 4.5 MPa. Ensure that the rubber hoses match the 1/4 inch needle valves inside the unit. If necessary, prepare needle valve adapters. When charging refrigerant, you are advised to use a safety valve to prevent refrigerant leakage during the removal of a rubber hose, which may cause frostbite. e: The nitrogen cylinder port should have a reducing valve, and the measuring range should be at least 4.0 MPa. f: Dry nitrogen. |