Item | Details |
---|---|
Description | 48-port 10GE interface card (FD-GK, SFP+) |
Part Number | 03059594 |
Model | CEL48XSFD-GK |
Silkscreen | CEL48XSFD-GK |
Appearance
The device where this card is to be installed cannot house SFUs or LPUs with mixed-card prevention labels. Otherwise, the device will be damaged.
Version Mapping
Product | First Supported Version | Unsupported Model | IDs of available slots | Limitations |
---|---|---|---|---|
CloudEngine 16804 | V200R019C10 | - | 1–4 | - |
CloudEngine 16808 | V200R019C10 | - | 1–8 | - |
CloudEngine 16816 | V200R019C10 | - | 1–16 | - |
Indicators
1. Running status indicator |
2. Port status indicator |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
RUN/ALM | Running status indicator | Green | Steady on | The card has been powered on but the system software is not running. |
Green | Slow blinking (0.5 Hz) | The card is working properly. | ||
Green | Fast blinking (4 Hz) | The card is loading the system software or is resetting. | ||
Red | Steady on | The card has a fault that affects services and cannot be rectified automatically (critical alarm about hardware). | ||
Yellow | Steady on | The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.) | ||
- | Port status indicator Two single-color indicators for each port Steady green: LINK indicator Blinking yellow: ACT indicator The indicator with an up arrowhead shows the status of the port on the top, and the indicator with a down arrowhead shows the status of the port at the bottom. |
Green | Steady on | The link on the port is connected. |
Green | Off | The link on the port is disconnected. | ||
Yellow | Fast blinking (15 Hz) | The port is transmitting or receiving data. | ||
Yellow | Off | The port is not transmitting or receiving data. |
Ports
1. Forty-eight 10GE optical ports |
Port | Connector Type | Description | Available Components |
---|---|---|---|
48 x 10GE optical ports | SFP+/SFP | Port for inputting and outputting 10GE/GE optical signals |
Functions and Features
Functions and Features | Description |
---|---|
Basic function | The card provides data packet processing and traffic management on 48 10GE optical ports. |
Maximum port density | If all LPUs are these cards:
|
10GE port | When the 10GE ports work in 10GE mode, they support SFP+ 10GE optical modules, 10GE high-speed cables, and AOC cables. When the 10GE ports work in GE mode, they support SFP GE optical modules and 1000BASE-T copper modules. When using a 1000BASE-T copper module, a port supports 100M/1000M auto-sensing. |
Hot swapping | Supported |
Restrictions and remarks | In V200R021C00 and earlier versions, this LPU is used with the CE-SFU16F-G. When the LPU is installed in slot 14, SFUs cannot work in 4+2 backup mode and can only work in 5+1 backup mode when the device works in six-SFU mode; SFUs cannot work in 3+1 backup mode or any other backup mode when the device works in four-SFU mode. |
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm (in.)] | 55.4 mm x 433.0 mm x 523.2 mm (2.18 in. x 17.05 in. x 20.60 in.) |
Dimensions with packaging (H x W x D) [mm (in.)] | 225 mm x 590 mm x 750 mm (8.86 in. x 23.23 in. x 29.53 in.) |
Weight without packaging [kg (lb)] | 6.7 kg (14.77 lb) |
Weight with packaging [kg (lb)] | 11.6 kg (25.58 lb) |
Typical power consumption [W] | 103 W |
Typical heat dissipation [BTU/hour] | 352 BTU/hour |
Static power consumption [W] | 85 W |
Static heat dissipation [BTU/hour] | 290 BTU/hour |
Maximum power consumption [W] | 193 W |
Maximum heat dissipation [BTU/hour] | 659 BTU/hour |
CPU | Quad-core, 1.4 GHz clock speed |
Memory | Standard 4 GB |
NOR Flash | Standard 128 MB |
CEL48XSFD-GK (03059594-001: 48-port 10GE interface card (FD-GK, SFP+))
Overview
Item | Details |
---|---|
Description | 48-port 10GE interface card (FD-GK, SFP+) |
Part Number | 03059594-001 |
Model | CEL48XSFD-GK |
Silkscreen | CEL48XSFD-GK |
Appearance
The device where this card is to be installed cannot house SFUs or LPUs with mixed-card prevention labels. Otherwise, the device will be damaged.
Version Mapping
Product | First Supported Version | Unsupported Model | IDs of available slots | Limitations |
---|---|---|---|---|
CloudEngine 16804 | V200R020C10 | - | 1–4 | If the card is used in V200R019C10SPC800, install the patch of V200R019SPH007 or a later version. |
CloudEngine 16808 | V200R020C10 | - | 1–8 | If the card is used in V200R019C10SPC800, install the patch of V200R019SPH007 or a later version. |
CloudEngine 16816 | V200R020C10 | - | 1–16 | If the card is used in V200R019C10SPC800, install the patch of V200R019SPH007 or a later version. |
Indicators
1. Running status indicator |
2. Port status indicator |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
RUN/ALM | Running status indicator | Green | Steady on | The card has been powered on but the system software is not running. |
Green | Slow blinking (0.5 Hz) | The card is working properly. | ||
Green | Fast blinking (4 Hz) | The card is loading the system software or is resetting. | ||
Red | Steady on | The card has a fault that affects services and cannot be rectified automatically (critical alarm about hardware). | ||
Yellow | Steady on | The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.) | ||
- | Port status indicator Two single-color indicators for each port Steady green: LINK indicator Blinking yellow: ACT indicator The indicator with an up arrowhead shows the status of the port on the top, and the indicator with a down arrowhead shows the status of the port at the bottom. |
Green | Steady on | The link on the port is connected. |
Green | Off | The link on the port is disconnected. | ||
Yellow | Fast blinking (15 Hz) | The port is transmitting or receiving data. | ||
Yellow | Off | The port is not transmitting or receiving data. |
Ports
1. Forty-eight 10GE optical ports |
Port | Connector Type | Description | Available Components |
---|---|---|---|
48 x 10GE optical ports | SFP+/SFP | Port for inputting and outputting 10GE/GE optical signals |
Functions and Features
Functions and Features | Description |
---|---|
Basic function | The card provides data packet processing and traffic management on 48 10GE optical ports. |
Maximum port density | If all LPUs are these cards:
|
10GE port | When the 10GE ports work in 10GE mode, they support SFP+ 10GE optical modules, 10GE high-speed cables, and AOC cables. When the 10GE ports work in GE mode, they support SFP GE optical modules and 1000BASE-T copper modules. When using a 1000BASE-T copper module, a port supports 100M/1000M auto-sensing. |
Hot swapping | Supported |
Restrictions and remarks | In V200R021C00 and earlier versions, this LPU is used with the CE-SFU16F-G. When the LPU is installed in slot 14, SFUs cannot work in 4+2 backup mode and can only work in 5+1 backup mode when the device works in six-SFU mode; SFUs cannot work in 3+1 backup mode or any other backup mode when the device works in four-SFU mode. |
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm (in.)] | 55.4 mm x 433.0 mm x 523.2 mm (2.18 in. x 17.05 in. x 20.60 in.) |
Dimensions with packaging (H x W x D) [mm (in.)] | 225 mm x 590 mm x 750 mm (8.86 in. x 23.23 in. x 29.53 in.) |
Weight without packaging [kg (lb)] | 6.7 kg (14.77 lb) |
Weight with packaging [kg (lb)] | 11.6 kg (25.58 lb) |
Typical power consumption [W] | 103 W |
Typical heat dissipation [BTU/hour] | 352 BTU/hour |
Static power consumption [W] | 85 W |
Static heat dissipation [BTU/hour] | 290 BTU/hour |
Maximum power consumption [W] | 193 W |
Maximum heat dissipation [BTU/hour] | 659 BTU/hour |
CPU | Quad-core, 1.4 GHz clock speed |
Memory | Standard 4 GB |
NOR Flash | Standard 128 MB |
CEL48XSFD-GK (03059594-002: 48-port 10GE interface card (FD-GK, SFP+))
Overview
Item | Details |
---|---|
Description | 48-port 10GE interface card (FD-GK, SFP+) |
Part Number | 03059594-002 |
Model | CEL48XSFD-GK |
Silkscreen | CEL48XSFD-GK |
Appearance
The device where this card is to be installed cannot house SFUs or LPUs with mixed-card prevention labels. Otherwise, the device will be damaged.
Version Mapping
Product | First Supported Version | Unsupported Model | IDs of available slots | Limitations |
---|---|---|---|---|
CloudEngine 16804 | V200R021C10SPC600 | - | 1–4 | If the card is used in V200R019C10SPC800, install the patch of V200R019SPH053 or a later version. If the card is used in V200R021C01SPC600, install the patch of V200R021SPH020 or a later version. |
CloudEngine 16808 | V200R021C10SPC600 | - | 1–8 | If the card is used in V200R019C10SPC800, install the patch of V200R019SPH053 or a later version. If the card is used in V200R021C01SPC600, install the patch of V200R021SPH020 or a later version. |
CloudEngine 16816 | V200R021C10SPC600 | - | 1–16 | If the card is used in V200R019C10SPC800, install the patch of V200R019SPH053 or a later version. If the card is used in V200R021C01SPC600, install the patch of V200R021SPH020 or a later version. |
Indicators
1. Running status indicator |
2. Port status indicator |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
RUN/ALM | Running status indicator | Green | Steady on | The card has been powered on but the system software is not running. |
Green | Slow blinking (0.5 Hz) | The card is working properly. | ||
Green | Fast blinking (4 Hz) | The card is loading the system software or is resetting. | ||
Red | Steady on | The card has a fault that affects services and cannot be rectified automatically (critical alarm about hardware). | ||
Yellow | Steady on | The card is in power-off state. (For example, the card has been forcibly powered off using the power off command or is about to start.) | ||
- | Port status indicator Two single-color indicators for each port Steady green: LINK indicator Blinking yellow: ACT indicator The indicator with an up arrowhead shows the status of the port on the top, and the indicator with a down arrowhead shows the status of the port at the bottom. |
Green | Steady on | The link on the port is connected. |
Green | Off | The link on the port is disconnected. | ||
Yellow | Fast blinking (15 Hz) | The port is transmitting or receiving data. | ||
Yellow | Off | The port is not transmitting or receiving data. |
Ports
1. Forty-eight 10GE optical ports |
Port | Connector Type | Description | Available Components |
---|---|---|---|
48 x 10GE optical ports | SFP+/SFP | Port for inputting and outputting 10GE/GE optical signals |
Functions and Features
Functions and Features | Description |
---|---|
Basic function | The card provides data packet processing and traffic management on 48 10GE optical ports. |
Maximum port density | If all LPUs are these cards:
|
10GE port | When the 10GE ports work in 10GE mode, they support SFP+ 10GE optical modules, 10GE high-speed cables, and AOC cables. When the 10GE ports work in GE mode, they support SFP GE optical modules and 1000BASE-T copper modules. When using a 1000BASE-T copper module, a port supports 100M/1000M auto-sensing. |
Hot swapping | Supported |
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm (in.)] | 55.4 mm x 433.0 mm x 523.2 mm (2.18 in. x 17.05 in. x 20.60 in.) |
Dimensions with packaging (H x W x D) [mm (in.)] | 225 mm x 590 mm x 750 mm (8.86 in. x 23.23 in. x 29.53 in.) |
Weight without packaging [kg (lb)] | 6.7 kg (14.77 lb) |
Weight with packaging [kg (lb)] | 11.6 kg (25.58 lb) |
Typical power consumption [W] | 103 W |
Typical heat dissipation [BTU/hour] | 352 BTU/hour |
Static power consumption [W] | 85 W |
Static heat dissipation [BTU/hour] | 290 BTU/hour |
Maximum power consumption [W] | 193 W |
Maximum heat dissipation [BTU/hour] | 659 BTU/hour |
CPU | Quad-core, 1.4 GHz clock speed |
Memory | Standard 4 GB |
NOR Flash | Standard 128 MB |