WebUI Layout
No. |
Function |
Description |
---|---|---|
1 |
Choose the corresponding first-level menu before you perform any operation over the WebUI. |
|
2 |
Under the first-level menu, choose the device to be queried or the parameter to be set under the second-level menu. |
|
3 |
|
|
4 |
Displays details of the queried information or parameter setting. |
|
5 |
Displays the current system time. |
|
6 |
Displays the current power grid scheduling mode and scheduling value of the system. |
|
7 |
Displays the signal strength of the SIM card. |
|
8 |
Displays the severities and number of active system alarms. You can click a number to access the alarm page. |
|
9 |
Selects the display language or chooses to log out. |
No. |
Parameter |
Description |
---|---|---|
1 |
Total active power of inverters |
|
2 |
Total energy yield of inverters on the current day |
|
3 |
Total energy yield of inverters |
|
4 |
(Total energy yield – Total power supply from grid) x CO2 emission reduction coefficient. If the result is negative, the value is zero. |
|
5 |
(Total energy yield – Total power supply from grid) x Revenue coefficient. If the result is negative, the value is zero. |
No. |
Parameter |
Description |
---|---|---|
1 |
Total active power of inverters |
|
2 |
Vector sum of the reactive power of inverters: Positive value indicates that power is transmitted to the grid and negative value indicates that power is transmitted from the grid. |
|
3 |
Vector sum of the active power and grid-tied active power |
|
4 |
Active power of the feed-in meter: Positive value indicates purchasing electricity and negative value indicates selling electricity. |
|
5 |
Reactive power of the feed-in meter: Positive value indicates that power is transmitted from the grid and negative value indicates that power is transmitted to the power grid. |
|
6 |
Total energy yield of inverters on the current day |
|
7 |
Energy yield of current day + Daily supply from grid – Daily feed-in to grid – Today's power supply from grid |
|
8 |
Current total negative active energy of the feed-in meter – Total negative active energy at 00:00 on the current day |
|
9 |
Current total positive active energy of the feed-in meter – Total positive active energy at 00:00 on the current day |
|
10 |
Total energy yield of inverters |
No. |
Parameter |
Description |
---|---|---|
1 |
Vector sum of the active power of inverters and Smart PCSs: Positive value indicates that energy is generated through the inverter and negative value indicates that energy is stored through the rectifier. |
|
2 |
Vector sum of the reactive power of inverters and Smart PCSs: Positive value indicates that power is transmitted to the grid and negative value indicates that power is transmitted from the grid. |
|
3 |
Total energy yield of inverters and Smart PCSs of the current day |
|
4 |
Total power supplied from the grid to inverters and Smart PCSs of the current day |
No. |
Parameter |
Description |
---|---|---|
1 |
Vector sum of the active power of inverters and Smart PCSs: Positive value indicates that energy is generated through the inverter and negative value indicates that energy is stored through the rectifier. |
|
2 |
Vector sum of the reactive power of inverters and Smart PCSs: Positive value indicates that power is transmitted to the grid and negative value indicates that power is transmitted from the grid. |
|
3 |
Vector sum of the active power and grid-tied active power |
|
4 |
Active power of the feed-in meter: Positive value indicates purchasing electricity and negative value indicates selling electricity. |
|
5 |
Reactive power of the feed-in meter: Positive value indicates that power is transmitted from the grid and negative value indicates that power is transmitted to the power grid. |
|
6 |
Total energy yield of the inverter and Smart PCS on a day |
|
7 |
Total power supplied from the grid to the inverter and Smart PCS on a day |
|
8 |
Energy yield of current day + Daily supply from grid – Daily feed-in to grid – Today's power supply from grid |
|
9 |
Current total positive active energy of the feed-in meter – Total positive active energy at 00:00 on the current day |