This document describes the SmartLogger3000 and SmartModule1000A01 in terms of installation, electrical connections, system operation, maintenance, and troubleshooting. BOM number: 02312SCU, 02312SCU-001, 02312SCU-002, 02312SCU-003, 02312SCU-004, 02312SCU-005, 02312SCU-006, 02312SCU-007, 02312SCU-008, 02312SCU-009, 02312SCU-010, 02312SGF, 02312SGG, 02312SGK and 02312SGJ.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Preparations and WebUI Login

Preparations and WebUI Login

Prerequisites

  • Operating system: Windows 7 or later
  • Browser: Chrome 52, Firefox 58, or Internet Explorer 9, or a later version is recommended.

Procedure

  1. Connect the network cable between the network port of the PC and the WAN or LAN port of the SmartLogger.
  2. Set the IP address for the PC on the same network segment as the SmartLogger IP address.

    Connected Port

    Item

    SmartLogger Default Value

    Example PC Setting

    LAN port

    IP address

    192.168.8.10

    192.168.8.11

    Subnet mask

    255.255.255.0

    255.255.255.0

    Default gateway

    192.168.8.1

    192.168.8.1

    WAN port

    IP address

    192.168.0.10

    192.168.0.11

    Subnet mask

    255.255.255.0

    255.255.255.0

    Default gateway

    192.168.0.1

    192.168.0.1

    • If the IP address of the WAN port is on the 192.168.8.1–192.168.8.255 network segment, the IP address of the LAN port is automatically switched to 192.168.3.10, and the default gateway is 192.168.3.1. If the connection port is a LAN port, the network configuration of the PC needs to be adjusted accordingly.
    • It is recommended that the PC be connected to the LAN port of the SmartLogger or the GE port of the SmartModule. When the PC is connected to the GE port of the SmartModule, adjust the network configuration of the PC to the configuration mode when the PC is connected to the LAN port of the SmartLogger.
    Figure 6-2 Changing the IP address of the PC (using Windows 10 as an example)

  3. Set LAN parameters.

    • If the SmartLogger is connected to a local area network (LAN) and a proxy server has been set, you need to cancel the proxy server settings.
    • If the SmartLogger is connected to the Internet and the PC is connected to the LAN, do not cancel the proxy server settings.

    1. Open Internet Explorer.
    2. Choose Tools > Internet Options.
    3. Click the Connections tab and then click LAN settings.
    4. Clear Use a proxy server for your LAN.

      Figure 6-3 LAN settings

    5. Click OK.
  4. Log in to the SmartLogger WebUI.
    1. In the address box of a browser, enter https://XX.XX.XX.XX (XX.XX.XX.XX is the IP address of the SmartLogger) and press Enter. The login page is displayed.If you log in to the WebUI for the first time, a security risk warning is displayed. Click Continue to this website to log in to the WebUI.

      • It is recommended that users use their own certificates. If the certificate is not replaced, the security risk warning will be displayed during each login.
      • After logging in to the WebUI, you can import a certificate under Maintenance > Security Settings > Network Security Certificate.
      • The imported security certificate needs to be bound to the SmartLogger IP address. Otherwise, the security risk warning will still be displayed during login.
      Figure 6-4 Security risk warning

    2. Specify Language, User Name, and Password, and click Log In.

      Figure 6-5 Login page

      Parameter

      Description

      Language

      Set this parameter as required.

      User Name

      Select admin.

      Password

      • The initial password is Changeme.
      • Use the initial password upon first power-on and change it immediately after login. Then, use the new password to log in again. To ensure account security, change the password periodically and keep the new password in mind. A password left unchanged for a long period of time may be stolen or cracked. If a password is lost, the device needs to be restored to its factory settings. In these cases, the user is liable for any loss caused to the PV plant.
      • If you enter incorrect passwords for five consecutive times in 5 minutes, your account will be locked out. You have to try again 10 minutes later.

      After logging in to the WebUI, a dialog box is displayed. You can view the recent login information. Click OK.

Follow-up Procedure

If any page is blank or a menu cannot be accessed after you log in to the WebUI, clear the cache, refresh the page, or log in again.