Which Models of Power Meters and EMIs Are Supported by the SmartLogger?
Vendor |
Model |
Export Limitation |
---|---|---|
ABB |
A44 |
- |
Acrel |
PZ96L |
Supported |
Algodue |
UPM209 |
Supported NOTE:
When the power meter connects to the SmartLogger, an external 120-ohm resistor needs to be connected to the RS485 bus of the power meter. For details, see the user manual of the power meter. |
- |
BackUp-CT |
Supported |
CHNT |
DTSU666 |
- |
- |
DTSU666-H |
Supported |
- |
DTSU666-HW |
Supported |
Elster |
A1800ALPHA |
- |
GAVAZZI |
EM210 |
- |
Janitza |
UMG103-CBM |
Supported |
Janitza |
UMG604 |
Supported |
Lead |
LD-C83 |
- |
MingHua |
CRDM-830 |
- |
Mitsubishi |
EMU4-BD1-MB |
Supported NOTE:
|
Mitsubishi |
ME110NSR-MB |
- |
Mitsubishi |
ME110SR-MB |
- |
Mitsubishi |
ME110SSR-MB |
- |
Mitsubishi |
M8FM-N3LTR |
- |
Mitsubishi |
ME110SSR-4APH |
- |
NARUN |
PD510 |
- |
NetBiter |
CEWE |
- |
People |
RM858E |
- |
Schneider |
PM2xxx |
- |
Schneider |
PM5100 |
- |
Schneider |
PM5300 |
- |
SFERE |
PD194Z |
- |
Socomec |
COUNTIS E43 |
Supported NOTE:
|
Toshiba |
S2MS |
- |
Wave Energy |
PWM-72 |
- |
WEG |
MMW03-M22CH |
Supported |
YDS |
YDS60-80 |
Supported NOTE:
Applicable only to three-phase power scenarios. |
YDS70-C16 |
Supported NOTE:
Applicable only to single-phase power scenarios. |
|
YDS60-C24 |
Supported NOTE:
Applicable only to three-phase power scenarios. |
Vendor |
Model |
EMI Information |
---|---|---|
ABB |
VSN800-12 |
Total irradiance, ambient temperature, and PV module temperature |
VSN800-14 |
Total irradiance, ambient temperature, PV module temperature, wind direction, and wind speed |
|
Gill MetPak Pro |
Gill MetPak Pro |
Total irradiance, ambient temperature, PV module temperature, wind direction, and wind speed |
Hukseflux SRx |
Hukseflux SRx |
Total irradiance and ambient temperature |
Ingenieurbüro Si-RS485TC |
Ingenieurbüro Si-RS485TC |
Total irradiance, ambient temperature, PV module temperature, and wind speed |
Kipp&Zonen |
SMPx series |
Total irradiance and ambient temperature |
Lufft |
WSx-UMB |
Total irradiance, ambient temperature, wind direction, and wind speed |
WSx-UMB(external sensors) |
Total irradiance, ambient temperature, PV module temperature, wind direction, and wind speed |
|
Meier-NT ADL-SR |
Meier-NT ADL-SR |
Total irradiance, ambient temperature, PV module temperature, and wind speed |
MeteoControl |
SR20-D2 |
Total irradiance and ambient temperature |
RainWise |
PVmet-150 |
Total irradiance, ambient temperature, and PV module temperature |
PVmet-200 |
Total irradiance, ambient temperature, PV module temperature, wind direction, and wind speed |
|
Soluzione Solare |
SunMeter |
Total irradiance and ambient temperature |
Jinzhou Licheng |
Jinzhou Licheng |
Total irradiance, ambient temperature, PV module temperature, wind direction, and wind speed |
Jinzhou Solargiga |
PC-4 |
Total irradiance, ambient temperature, PV module temperature, wind direction, and wind speed |
Handan |
RYQ-3 |
Total irradiance, ambient temperature, PV module temperature, wind direction, and wind speed |
Sensor ADAM NOTE: