(Optional) Configuring Optical Module Attributes
Context
After configuring optical module attributes on a PON interface, you can monitor the interface status on the NMS.
Procedure
- Run system-view
The system view is displayed.
- Run interface pon interface-number
The PON interface view is displayed.
- Run laser { auto | off | on [ time-value ] }
The laser working mode of the PON interface optical module is configured.
The default laser working mode is auto.
- Run optical-module threshold bias { lower-limit lower-limit | upper-limit upper-limit }*
The lower alarm threshold and upper alarm threshold of the bias current are set for the optical module.
The recommended value of lower-limit is 2.
The recommended value of upper-limit is 70.
- Run optical-module threshold rx-power { lower-limit lower-limit | upper-limit upper-limit }*
The lower alarm threshold and upper alarm threshold of the receiving optical power are set for the optical module.
The recommended value of lower-limit is -35.00.
The recommended value of upper-limit is 1.00.
- Run optical-module threshold tx-power { lower-limit lower-limit | upper-limit upper-limit }*
The lower alarm threshold and upper alarm threshold of the transmitting optical power are set for the optical module.
The recommended value of lower-limit is -1.00.
The recommended value of upper-limit is 7.00.
- Run optical-module threshold temperature { lower-limit lower-limit | upper-limit upper-limit }*
The lower alarm threshold and upper alarm threshold of the temperature are set for the optical module.
The recommended value of lower-limit is -10.
The recommended value of upper-limit is 100.
- Run optical-module threshold voltage { lower-limit lower-limit | upper-limit upper-limit }*
The lower alarm threshold and upper alarm threshold of the voltage are set for the optical module.
The recommended value of lower-limit is 2.97.
The recommended value of upper-limit is 3.63.