Default Settings for CT1/PRI Interfaces
Default Settings for CT1/PRI Interfaces
This section provides the default settings for a CT1/PRI interface.
Table 6-1 Default settings for a CT1/PRI interface
Parameter
Default Setting
Working mode of the 1E1T1-M/2E1T1-M interface card
e1-data (CE1/PRI mode)
Cable type applicable to the CT1/PRI interface
120 ohm balanced cable (twisted pair)
Attenuation or length of the transmission line matching the CT1/PRI interface
long -7.5db
Clock mode
Slave clock mode
Line idle code type
0x7e
Interframe filling tag type and minimum number of interframe filling tags
Interframe filling tag type: 0x7e; minimum number of interframe filling tags: 4
Frame format
ESF
Whether to invert data
No
Whether to perform RAI detection
Yes
Alarm thresholds
Alarm Indication Signal (AIS) alarm threshold: level 1
Loss of Frame Alignment (LFA) alarm threshold: level 1
Loss of Signal (LOS) alarm threshold: The value of pulse-detection is 176 and the value of pulse-recovery is 22, indicating that a LOS alarm is generated if less than 22 pulses are detected within 176 pulse intervals.