No relevant resource is found in the selected language.
Your browser version is too early. Some functions of the website may be unavailable. To obtain better user experience, upgrade the browser to the latest version.
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CE1/PRI Interface Fails to Communicate with a Serial Interface (V.35DTE/DCE)
CE1/PRI Interface Fails to Communicate with a Serial Interface (V.35DTE/DCE)
Fault Symptom
A CE1/PRI interface fails to communicate with a serial interface (V.35DTE/DCE).
Procedure
Check whether the protocol converter is used and whether it works properly.
Run the usinge1 command in the CE1/PRI interface view to configure the CE1/PRI interface to work in E1 (non-channelized) mode.
Adjust the rate of the serial interface.
When the serial interface works in DCE mode, run the baudrate2048000 command to set the baud rate of the serial interface in synchronous mode to 2048000 bit/s.
When the serial interface works in DTE mode, run the virtualbaudrate2048000 command to set the virtual baud rate of the serial interface in synchronous mode to 2048000 bit/s.
Ensure that the CE1/PRI interface and serial interface use the same CRC mode.