Default Settings for T1-F Interfaces
Default Settings for T1-F Interfaces
This section provides the default settings for a T1-F interface.
Table 9-1 Default settings for a T1-F interface
Parameter
Default Setting
Working mode of the 1E1T1-F/2E1T1-F interface card
e1-f (E1-F mode)
Working mode of the T1-F interface
Framed mode
Timeslot bundling
All timeslots bundled into one channel set, with a rate of 1536 kbit/s (The default rate of a timeslot is 64 kbit/s.)
Attenuation or length of the transmission line matching the T1-F interface
long -7.5db
Clock mode
Line clock mode (slave)
Line idle code
0x7e
Interframe filling tag type and minimum number of interframe filling tags
Interframe filling tag type: 0x7e; minimum number of interframe filling tags: 4
CRC mode
16-bit CRC
Whether to invert data
No
Whether to perform RAI detection (in framed mode)
Yes
Alarm thresholds
Alarm Indication Signal (AIS) alarm threshold: level 1
Loss of Frame Alignment (LFA) alarm threshold: level 1
Loss of Signal (LOS) alarm threshold: The value of pulse-detection is 176 and the value of pulse-recovery is 22, indicating that a LOS alarm is generated if less than 22 pulses are detected within 176 pulse intervals.