Setting Parameters for Physical Voice Interfaces
Prerequisites
The working mode of the device has been set to PBX. For details on how to configure the working mode of the device, see Configuring a Device to Work in PBX Mode.
Setting Parameters for an FXS Interface
Step |
Action |
Command |
Description |
---|---|---|---|
1 |
Enter the system view. |
system-view |
- |
2 |
Enter the voice view. |
voice |
- |
3 |
Enter the FXS interface view. |
port fxs slotid/subcardid/portid |
By default, the region identifier is China mainland. |
4 |
Set physical attributes for the FXS interface. |
|
- |
5 |
Set electrical attributes for the FXS interface. |
|
- |
Setting Parameters for an FXO Interface
Step |
Action |
Command |
Description |
---|---|---|---|
1 |
Enter the system view. |
system-view |
- |
2 |
Enter the voice view. |
voice |
- |
3 |
Enter the FXO interface view |
port fxo slotid/subcardid/portid |
- |
4 |
Set the gain. |
gain { send sendgain-value | receive recvgain-value } |
If the RBT played for the caller through the FXO interface is loud, the FXO interface may fail to detect the busy tone from the caller. Therefore, if the caller hangs up before the call is answered, the called user still hears the ring tone for a period. This problem can be solved by adjusting the send gain on the FXO interface. |
5 |
Set the impedance. |
impedance { dc value | ac value } |
- |
6 |
Set the ring current. |
ring { minimum-duration min-duration-value | maximum-interval max-interval-value | frequence frequence-value | ac-amplitude ac-amplitude-value | offset offset-value } |
- |
7 |
Set the feed. |
feed { maximum-voltage max-vol-value | minimum-voltage min-vol-value | maximum-current max-current-value | minimum-current min-current-value } |
- |
Setting Parameters for a BRA Interface
Step |
Action |
Command |
Description |
---|---|---|---|
1 |
Enter the system view. |
system-view |
- |
2 |
Configure the working mode of the 2BST interface card. |
set workmode slot slot-id bri bri-voice { nt-mode | te-mode } |
When the BRA interface connects to an ISDN phone, set the working mode of the 2BST interface card to nt-mode. When the BRA interface connects to an ISDN network, set the working mode of the 2BST interface card to te-mode. NOTE:
After this command is executed, the configured service is invalid. After you run this command, the system asks you whether to reset the 2BST interface card. If you enter Y, the system resets the 2BST interface card to make the configuration take effect. If the system does not reset the 2BST interface card, run the reset slot command to reset the 2BST interface card. |
3 |
Enter the voice view. |
voice |
- |
4 |
Enter the BRA interface view. |
port bra slotid/subcardid/portid |
- |
6 |
Enable BRA interface Layer 2 monitoring. |
l2-monitor enable |
- |
7 |
Set the working mode. |
work-mode { p2p | p2mp } |
- |
8 |
Enable remote power supply. |
remote-power enable |
- |
9 |
Enabled the alarm function. |
alarm enable |
- |
Setting Parameters for a VE1 Interface
Step |
Action |
Command |
Description |
---|---|---|---|
1 |
Enter the system view. |
system-view |
- |
2 |
Configure the E1 card as the E1 voice card. |
set workmode slot slot-id e1t1 e1-voice |
After this command is executed, the configured service is invalid. The system asks you whether to reset the E1 voice card. If you enter Y, the system resets the E1 voice card to make the configuration take effect. If the system does not reset the E1 voice card, run the reset slot command to reset the E1 voice card. |
3 |
Enter the voice view. |
voice |
- |
4 |
Enter the VE1 interface view. |
port ve1 slotid/subcardid/portid |
- |
5 |
Set the signaling mode. |
signal { ccs | cas } |
When the VE1 interface is bound to a PRA trunk, configure common channel signaling (CCS) on the VE1 interface. When the VE1 interface is bound to an E1R2 trunk, configure channel associated signaling (CAS) on the VE1 interface. By default, a VE1 interface uses the CCS mode. |
6 |
Set the access digital section mode. |
access-mode { digital | direct } |
- |
7 |
Enable the CRC4 function. |
crc4 enable |
- |
8 |
Set the CRC alarm threshold. |
crc-alarm-threshold { es es-threshold | cses cses-threshold | dm dm-threshold } |
- |
9 |
Enable VE1 interface Layer 2 monitoring. |
l2-monitor enable |
- |
10 |
Enable the PCM alarm function. |
pcm-alarm |
- |
11 |
Set the impedance of the VE1 interface. |
impedance impedance-value |
- |
Verification
Action |
Command |
Expected Result |
---|---|---|
Verify the FXS interface configuration. |
display voice port fxs [ slotid/subcardid/portid ] |
The parameter values in the command output are consistent with the settings. |
Verify the FXO interface configuration. |
display voice port fxo [ slotid/subcardid/portid ] |
|
Verify the BRA interface configuration. |
display voice port bra [ slotid/subcardid/portid ] |
|
Verify the VE1 interface configuration. |
display voice port ve1 [ slotid/subcardid/portid ] |