Setting Parameters for a BRA Interface
Context
A basic rate access (BRA) interface connects to an ISDN phone. On the device, you can enable the BRA interface Layer 2 monitoring, remote power supply, and alarm functions, and set the working mode and Layer 1 activation mode on a BRA interface.
Procedure
- Run:
system-view
The system view is displayed.
- Run:
set workmode slot slot-id bri bri-voice { nt-mode | te-mode }
The working mode of the 2BST interface card is configured.
When the BRA interface connects to ISDN phones, set the working mode of the 2BST interface card to nt-mode. When the device is configured to work in H.248 AG mode, the BRA interface can only connect to ISDN phones.
After this command is executed, the configured service takes no effect.
After you using this command, the system displays a message asking you whether to reset the 2BST interface card. If you enter Y, the system resets the 2BST interface card to make the configuration take effect. Otherwise, run the reset slot command to restart the 2BST interface card.
- Run:
voice
The voice view is displayed.
- Run:
port bra slotid/subcardid/portid
The BRA interface view is displayed.
- (Optional) Run:
l2-monitor enable
BRA interface Layer 2 monitoring is enabled.
- (Optional) Run:
work-mode { p2p | p2mp }
The working mode is set.
- (Optional) Run:
remote-power enable
Remote power supply is enabled.
- (Optional) Run:
alarm enable
The alarm function is enabled.