0xF00EA0014 Abnormal Port Link
Description
The link to a port housing an optical module is down, because the cable connecting the front-end port and the application server or another device is removed, and a fault on the optical module or port occurs.
Applicable Model
Applicable to all models.
Impact on the System
The application server or other devices cannot communicate with the storage system through the front-end port.
Possible Causes
- Cables are not securely connected or are damaged.
- The optical module where the port or its peer port resides is faulty.
- The port or its peer port is faulty.
Procedure
- Check cables.
- Check whether the host port and its peer port have optical modules.
- Replace the modules where the port and its peer port reside. If the alarm persists=> Step4.
- Collect related information and contact technical support engineers.