0xF00D1004A A Spare Interface Module Is Inserted Into An Incorrect Slot
0xF00D1004A A Spare Interface Module Is Inserted Into An Incorrect Slot
Description
A spare interface module is inserted into an incorrect slot.
Applicable Model
Applicable to all models.
Attribute
ID
Event Type
Event Level
Automatically Cleared
0xF00D1004A
Alarm
Major
Yes
Impact on the System
If the spare interface module is inserted into an unused slot, the interface module will not be powered on, and all ports on the interface module cannot carry services.
Possible Causes
The spare interface module is inserted into an unused slot or a slot with the incorrect configuration.
Procedure
Remove the spare interface module from the slot. If the alarm persists=> Step2.
Collect related information and contact technical support engineers.