0xF00D80119 Storage Pool Remaining Capacity Is Insufficient
0xF00D80119 Storage Pool Remaining Capacity Is Insufficient
Description
The used capacity of the storage pool has reached the alarm threshold. The default alarm threshold is 80% of the total capacity. You can run the "change storage_pool general pool_id=? full_threshold=?" command to change the alarm threshold.
Applicable Model
Applicable to all models.
Attribute
ID
Event Type
Event Level
Automatically Cleared
0xF00D80119
Alarm
Major
Yes
Impact on the System
Some storage pool services will become unavailable.
Possible Causes
The used capacity of the storage pool reaches the threshold.
Procedure
Check whether unused data exists in the storage pool.
If yes, delete unused data.
Expand the capacity of the storage pool based on the alarm details.
If the HyperCDP schedule is configured, you are advised to enable the automatic deletion function of the storage pool. If the alarm persists=> Step2.