- About This Document
- Overview
- Event Links
Troubleshooting Events
- 0x1000010A000B Disk Domain Reconstruction Failed
- 0x1000010A000E Disk Pre-Copy Failed
- 0x100310001 Abnormal GaussDB Service On The Node
- 0x100F000B0017 An Unrepairable Sector Was Discovered
- 0x100F000B0040 ISCSI Link Of A Heterogeneous Array Is Abnormal
- 0x100F00150036 Data Sent To A Storage Array Port By The Host Failed To Be Verified
- 0x100F001B0021 A HyperCDP Schedule Failed To Be Executed
- 0x100F00310005 Task Execution Is Prevented
- 0x100F00310006 Task Execution Is Enabled
- 0x100F00310007 Task Execution Is Prevented
- 0x100F00310008 Task Execution Is Enabled
- 0x100F00C9001D System Processes Time Out
- 0x100F00CF0027 A Controller Restarts Or Powers On Successfully
- 0x100F00CF0034 A Controller Is Isolated
- 0x100F00CF0037 Controller Is About To Restart
- 0x100F00CF003D Controller Exception Is Being Processed
- 0x100F00CF003F The Port On The SAS Chip Inside The Controller Has Too Many Bit Errors
- 0x100F00CF0040 The Controller Is Being Repaired
- 0x100F00CF0042 The Chips Of Controller Repaired Successfully
- 0x100F00D10037 Interface Module Exception Is Being Processed
- 0x100F00D10038 Speeds Of The Port And Optical Module In The Port Are Not The Same On An Interface Module
- 0x100F00D1003C The Chips Of An Interface Module Are Repaired Successfully
- 0x100F00D40001 The Host FC Initiator Is Incompatible With The Array FC Driver
- 0x100F00D40002 The Remote FC Port Refused The Connection Request Of The Array FC Driver
- 0x100F00D8002D The Storage Pool Protection Capacity Reaches The Lower Threshold
- 0x100F00D8002E The Storage Pool Protection Capacity Reaches The Upper Threshold
- 0x100F00D80032 The Protection Capacity Percentage Of The Storage Pool Is Lower Than The Higher Threshold Of The Protection Capacity
- 0x100F00DD0003 The Remote Replication Consistency Group Enters The To-Be-Recovered State Data On The Primary End Cannot Be Synchronized To The Remote End
- 0x100F0104004B The System Generated Large Amount Of Events
- 0x100F0104004C Failed To Send An Alarm To The Destination Address
- 0x100F0104004D An Event Was Dumped And Cleared
- 0x100F0104004E Failed To Delete An Information Collection File
- 0x100F01060063 The Controller Is Overloaded
- 0x100F01070003 The Remote Replication Pair Enters The To-Be-Recovered State Data On The Primary End Cannot Be Synchronized To The Remote End
- 0x100F010C0015 ISCSI Initiator Login Failed
- 0x100F010C002F Number Of Initiators Exceeds The System Limit
- 0x100F010C0030 Number Of Initiator Connections On A Port Exceeds The System Limit
- 0x100F010C0031 Initiator IP Address Is Changed
- 0x100F010D0016 Time Spent In Upgrade Was Long
- 0x100F010D0024 The Upgrade Fails
- 0x100F010D0026 System Rollback Failed
- 0x100F010D0027 Upgrade Failed
- 0x100F010D0031 Failed To Dispatch An Upgrade Package
- 0x100F010D0038 Performance Of The SmartQoS Policy Failed To Reach The Specified Control Objective
- 0x100F0170006 Power Module Incompatible
- 0x100F0170008 Multi-Vendor Power Modules In The Same Enclosure
- 0x100F0C9000C Controller Failed To Be Powered On Again
- 0x100F0C90065 System Engine Is Working In Single-Controller Mode
- 0x10A0001 Disk Domain Is Degraded
- 0x10A0002 Disk Domain Is Faulty
- 0x10A0003 Disk Domain Is Offline
- 0x10A0006 Inconsistent Disk Types
- 0x10A0008 A Disk Is Removed From A Disk Domain
- 0x10A0020 A New Disk Fails To Be Added To The Disk Domain
- 0x11C36D0001 NTP Failed To Synchronize Time
- 0x1400D80001 Current Usage Of The Backup Storage Pool Exceeds The Threshold
- 0x1FFFFFFFFFFFFFFC Testing The Alarm Function
- 0x200F000A012F Failed To Restore An Isolated Member Disk
- 0x200F000B0267 Reverse Synchronization Of A Clone Pair Is Stopped Abnormally
- 0x200F000B0268 Synchronization Of A Clone Pair Is Stopped Abnormally
- 0x200F001B005B Succeeded In Canceling Snapshot Rollback
- 0x200F001B005C Failed To Cancel Snapshot Rollback
- 0x200F001B0085 Succeeded In Canceling The Restoration Of A HyperCDP Object
- 0x200F001B0086 Failed To Cancel The Restoration Of A HyperCDP Object
- 0x200F001B0093 Succeeded In Canceling The Restoration Of A HyperCDP Consistency Group
- 0x200F001B0094 Failed To Cancel The Restoration Of A HyperCDP Consistency Group
- 0x200F00710038 Failed To Back Up Internal Key Management Service Data
- 0x200F00C90088 Succeeded In Deleting All Configurations Of System
- 0x200F00C90089 Failed To Delete All Configurations Of System
- 0x200F00C901A9 Failed To Delete All Configurations Of System
- 0x200F00CF0022 Failed To Start A Controller
- 0x200F00CF0025 The System Failed To Restart A Controller
- 0x200F00CF003A The Heartbeat Connection Between A Controller And A Management Module Is Interrupted
- 0x200F00D8011D Storage Pool Capacity Is Used Up
- 0x200F010A0015 Failed To Upgrade SES Firmware
- 0x200F010D0018 Failed To Start Deleting The Hot Patch
- 0x200F010D001B Failed To Start The Upgrade
- 0x200F010D001E Failed To Start The Upgrade Of Disk Firmware
- 0x200F010D0021 Failed To Start The Upgrade Of Disk Converter Firmware
- 0x200F010D0024 Failed To Start Rollback
- 0x200F010D0029 Failed To Start The Dispatching Process Of An Upgrade Package
- 0x200F022E000A Failed To Start The Upgrade Of System Disk Firmware
- 0x200F0337000C Server Link Is Down
- 0x200F0D1000D The System Failed To Power Off An Interface Module
- 0x200F0D10010 The System Failed To Power On An Interface Module
- 0xF00060004 Expansion Port Is Faulty
- 0xF00060008 Controller Is Connected To An Unsupported Disk Enclosure
- 0xF0006001A Management Network Port Is Disconnected
- 0xF0006001F The Cable Is Incorrectly Connected To A Port
- 0xF00060020 The Cable Between Two Ports Is Incorrectly Connected
- 0xF00060021 The Cable Between Two Ports Is Not Connected According To The Standard Network
- 0xF00060022 The Cable Is Not Connected To A Port
- 0xF00060023 The Cable Between Two Ports Is Not Connected
- 0xF00060025 Cable Length Does Not Meet Specifications
- 0xF000A0015 The System Failed To Monitor A Disk In The Disk Enclosure
- 0xF000A0106 Unrecognizable Disk
- 0xF000A0107 Disk Is About To Fail
- 0xF000A0118 The System Failed To Monitor A Disk In The Controller Enclosure
- 0xF000A0119 Working Rate Of A Disk Is Abnormal
- 0xF000A011B The Number Of Connected Disks Exceeds The Upper Limit Of The System
- 0xF000A0120 Disk Temperature Exceeds The Upper Limit
- 0xF000A0121 Slow Disk Response
- 0xF000A0123 Incompatible Disk Model
- 0xF000A0128 Failed To Authenticate Self-Encrypting Disk Access
- 0xF000A0129 Failed To Authenticate A Self-Encrypting Disk Key
- 0xF000A013B The Disk Is Isolated
- 0xF000B0052 Incompatible Heterogeneous Array Connected To The System
- 0xF000B0063 An External LUN Has A Link To Only One Controller
- 0xF000B0064 External LUN Offline
- 0xF000B0065 External LUN Faulty
- 0xF000B0102 External LUN Is Changed To Command Device
- 0xF000B0108 Number Of The Connected Remote Links Has Exceeded The Upper Limit
- 0xF000B0109 Number Of The Connected Remote Arrays Has Exceeded The Upper Limit
- 0xF000B010B Failed To Register Paths From The Local Storage Array To Heterogeneous Storage Array
- 0xF000B012D Write Protection For Some File Systems, LUNs, Or Historical Performance Data Storage Space
- 0xF000B012E The Link From The Local Storage To The External Storage Does Not Meet The Redundancy Requirements
- 0xF0015001B Link Between A Host And Storage Array Is Unstable
- 0xF0015001D Ultrapath Incompatible With Storage Array Software
- 0xF0015001E The Operating System Type Of The Array Host Is Inconsistent With That Of The Associated Physical Host
- 0xF00150021 The Universal Multipathing Software And UltraPath Jointly Take Over The LUNs
- 0xF00150023 UltraPath Incompatible With Operating System Kernel
- 0xF00150024 Paths Between The Host And Storage Array Do Not Meet Redundancy Requirements
- 0xF00150025 Paths Between The Host And Storage Array Do Not Meet Redundancy Requirements
- 0xF00150027 LUNs Mapped To The Host Have No Redundant Links To The Storage Array
- 0xF00150028 LUNs Mapped To The Host Have No Redundant Links To Controllers
- 0xF00170014 Power Module Has No Input
- 0xF00170017 The System Failed To Monitor A Power Module
- 0xF00170018 Power Module Type Is Mismatched
- 0xF00170019 Power Module Is Faulty
- 0xF0017001A The Power Module Is Incompatible With The Controller
- 0xF00270038 Remote Replication Is Interrupted
- 0xF00270039 Remote Replication Is Unavailable
- 0xF00270137 Remote Replication Is Automatically Split
- 0xF00310004 The Space That Stores Event Logs Is To Be Used Up
- 0xF0050001 Expansion Module Is Removed
- 0xF0060002 Expansion Port Link Down
- 0xF0060004 A Port Is Disconnected
- 0xF0060006 Expansion Port Partially Damaged
- 0xF0060010 The Expansion Port Is Isolated
- 0xF0060011 Network Port Is Working In Half-Duplex Mode
- 0xF00710006 SSO Server Is Unavailable
- 0xF00A0001 Disk Is Faulty
- 0xF00A000C A Disk Is In The Single-Link Status
- 0xF00B0002 A Medium Error Occurred On A LUN
- 0xF00C9013D IP Address Conflict
- 0xF00C90150 Components In The System Are Abnormal
- 0xF00C90151 Components In The System Are Abnormal And Have Been Repaired Automatically
- 0xF00C90152 Management DNS Server Is Unavailable
- 0xF00C90153 The Process Of Daemon Is Faulty
- 0xF00CA000E The Password Of The User Is About To Expire
- 0xF00CA000F The Password Of The User Has Expired
- 0xF00CA001B The Super Administrator Needs To Review User Account Information
- 0xF00CE0015 Failed To Monitor Controllers Enclosure
- 0xF00CE0017 The Number Of Disk Enclosures Connected To An Expansion Port Exceeds The System Specification
- 0xF00CE002A Disk Enclosure Is Working In Single Link State
- 0xF00CE002E The System Failed To Monitor The Rear Panel Of The Enclosure
- 0xF00CE0031 Faults Occurred On An Enclosure
- 0xF00CE0032 Failed To Identify A Controller Enclosure Or Disk Enclosure
- 0xF00CE0038 The Enclosure Type Is Mismatched
- 0xF00CE003D The Number Of Disk Enclosures Connected To An Expansion Port Exceeds The System Specification
- 0xF00CE003E An Unsupported Disk Enclosure Is Connected To The System
- 0xF00CE003F Model Of An Expansion Module In The Disk Enclosure Is Not Supported By The System
- 0xF00CF0035 The System Is Abnormal
- 0xF00CF005D CPU Utilization Is Too High
- 0xF00CF005E Remaining Available Memory Is Too Low
- 0xF00CF005F The Controller Is Faulty
- 0xF00CF0060 Incorrect Controller Memory Capacity
- 0xF00CF0061 Communication Link Fault Among The Controller And Management Modules
- 0xF00CF0070 Types Of Controllers In The Enclosure Are Different
- 0xF00CF0072 Controller Running Status Is Abnormal
- 0xF00CF0076 Failed To Monitor The Controller
- 0xF00CF0077 The Monitor Link Between The Expansion Module And The Enclosure Is Faulty
- 0xF00CF0079 Write Protection Is Enabled On A Controller
- 0xF00CF007A Write Protection Is Enabled On A Controller
- 0xF00CF007B The Slot ID Of The Controller Module Is Incorrect
- 0xF00CF007D The Controller Is Being Repaired
- 0xF00CF007F The Controller Power-on Times Out
- 0xF00CF0084 Heat Dissipation System Of The Controller Is Faulty
- 0xF00CF0085 Number Of ISCSI Initiator Connections On A Controller Exceeds The Upper Limit
- 0xF00CF0086 Number Of ISCSI Commands On A Controller Exceeds The Upper Limit
- 0xF00D00014 Abnormal Communication Between Expansion Modules
- 0xF00D00017 Failed To Synchronize The Firmware Version Of An Expansion Module
- 0xF00D00018 Expansion Module Is Faulty
- 0xF00D0001D The Expansion Module Speed Does Not Meet Specifications
- 0xF00D0001F The Expansion Module Cannot Identify The Enclosure Type
- 0xF00D00021 Expansion Module Is Being Repaired
- 0xF00D00022 Expansion Module Repair Times Out
- 0xF00D00023 Failed To Repair An Expansion Module
- 0xF00D00026 The Power Module Is Incompatible With The Expansion Module
- 0xF00D00028 Heat Dissipation System Of The Expansion Module Is Faulty
- 0xF00D00029 Types Of Expansion Modules In The Disk Enclosure Are Different
- 0xF00D0002A Memory Capacity Of Expansion Module Is Incorrect
- 0xF00D1001E Interface Module Cannot Be Monitored
- 0xF00D10038 PCIe Channel Between An Interface Module And A Controller Is Abnormal
- 0xF00D10039 The Shared SAS Expansion Module Firmware Is Incompatible With Storage Array Software
- 0xF00D1003B Management Module Is Removed
- 0xF00D1003C The Management Module Is Faulty
- 0xF00D1003D Interface Module Is Faulty
- 0xF00D10044 Interface Module Not Supported
- 0xF00D10045 Interface Module Inserted Into An Incorrect Slot
- 0xF00D10047 Communication Link Fault Between The Management Module And Controller
- 0xF00D10049 An Interface Module Is Not Inserted Into The Recommended Slot
- 0xF00D1004A A Spare Interface Module Is Inserted Into An Incorrect Slot
- 0xF00D1004B Number Of ISCSI Initiator Connections On An Interface Module Exceeds The Upper Limit
- 0xF00D1004C Incorrect Working Mode Of An Interface Module
- 0xF00D20014 BBU Module Cannot Be Monitored
- 0xF00D20019 The BBU Type Does Not Comply With The System Specification
- 0xF00D2001B BBU Module Temperature Is Below The Lower Limit
- 0xF00D2001C BBU Module Is Faulty
- 0xF00D2001D BBU Module Reaches Its Expiration Date Or Is Aging
- 0xF00D2001E BBU Module Is About To Expire
- 0xF00D30014 Fan Module Cannot Be Monitored
- 0xF00D30015 Fan Module Is Faulty
- 0xF00D30016 Faulty Fan Module
- 0xF00D30017 Faulty Fan Module
- 0xF00D80119 Storage Pool Remaining Capacity Is Insufficient
- 0xF00D80120 Storage Pool Capacity Is About To Be Used Up
- 0xF00D80125 The Model Of The New Disk Is Different From The Replaced One And Cannot Be Added To The Disk Domain
- 0xF00D80142 The Effective Capacity Of The System Is Insufficient
- 0xF00D80143 The Effective Capacity Of The System Is About To Be Used Up
- 0xF00D80144 The Effective Capacity Of The System Is Used Up
- 0xF00D80148 The Used Effective Capacity Is Not As Expected
- 0xF00E00042 No Redundant Link Exists Between The Local Array And Remote Device
- 0xF00E00043 Remote Device Is Faulty
- 0xF00E00047 The Link Authentication Between Storage Devices Failed
- 0xF00E00049 The Replication Link Between The Storage Array And The Interface Module Of The Remote Device Does Not Meet The Redundancy Requirements
- 0xF00EA0014 Abnormal Port Link
- 0xF00EA0015 Optical Module Cannot Be Monitored
- 0xF00EA0018 The System Failed To Monitor An Optical Or Electrical Module
- 0xF00F40001 The License Is Invalid
- 0xF01080015 Port Has Too Many Bit Errors
- 0xF0108001D Port Negotiated Rate Is Smaller Than The Allowed Maximum
- 0xF01080049 Management Network Port Is Disconnected
- 0xF010A0055 A Disk Domain Has A Medium Error
- 0xF010A0057 Internal Resource Of The Disk Domain Is Not Enough
- 0xF010A005E The Self-Encrypting Disk Key In A Disk Domain Has Expired
- 0xF010A005F The Self-Encrypting Disk Key In A Disk Domain Is About To Expire
- 0xF010A0066 The Hot Spare Space Of The Disk Domain Is Insufficient
- 0xF010B0005 The Amount Of Written Data Reaches The Specification Of Effective Capacity
- 0xF010B0006 The Amount Of Written Data Exceeds The Specification Of Effective Capacity
- 0xF010C0014 Number Of Initiators Connected To A Port Exceeds The Upper Limit
- 0xF010D0027 BBU Firmware Is Incompatible With Storage Array Software
- 0xF010D0028 Interface Module Firmware Is Incompatible With Storage Array Software
- 0xF010D0032 The Management Module Firmware Is Incompatible With Storage Array Software
- 0xF01320002 Assistant Cooling Unit Removed
- 0xF01320004 The System Failed To Monitor Assistant Cooling Unit
- 0xF01320005 Assistant Cooling Unit Is Unrecognizable
- 0xF01320006 The Auxiliary Heat Dissipation Module Is Incompatible With The Controller Module
- 0xF01320044 Assistant Cooling Unit Is Faulty
- 0xF0170002 Power Module Is Removed
- 0xF0170004 Power Module Temperature Exceeds The Upper Limit
- 0xF0170005 Power Module Input Is Abnormal
- 0xF02440001 Number Of Commands On A Port Exceeds The System Limit
- 0xF02440002 Number Of Commands On A Module Exceeds The System Limit
- 0xF032C0001 The SSH Service Is Abnormal
- 0xF032C0002 The FTP Service Is Abnormal
- 0xF032C0003 NTP Time Synchronization Is Abnormal
- 0xF032C0004 The Network Protocol Stack Of A Controller Is Abnormal
- 0xF032C0005 The Process CPU Utilization Is Too High
- 0xF032C0006 The Process Memory Usage Is Too High
- 0xF032C0007 A Directory Is Oversized
- 0xF032C0008 Excessive Files Exist In A Directory
- 0xF03360001 Average CPU Utilization Exceeded The Threshold
- 0xF03360002 Utilization Exceeded The Threshold
- 0xF03360004 Average I/O Response Time Exceeded The Threshold
- 0xF03360007 Time Since Last Synchronization Exceeded The Threshold
- 0xF03360008 Average CPU Utilization Exceeded The Threshold
- 0xF03360009 Utilization Exceeded The Threshold
- 0xF0336000B Average I/O Response Time Exceeded The Threshold
- 0xF0336000E Time Since Last Synchronization Exceeded The Threshold
- 0xF0336000F Average CPU Utilization Exceeded The Threshold
- 0xF03360010 Utilization Exceeded The Threshold
- 0xF03360012 Average I/O Response Time Exceeded The Threshold
- 0xF03360015 Time Since Last Synchronization Exceeded The Threshold
- 0xF03370002 Server Is Unavailable
- 0xF03370003 The SMTP Server Is Unavailable
- 0xF03370004 Syslog Server Is Unavailable
- 0xF03370005 Alarm Dump Server Is Unavailable
- 0xF03370006 Performance Dump Server Is Unavailable
- 0xF03370007 LDAP Server Is Unavailable
- 0xF03370008 Key File Backup Server Is Unavailable
- 0xF0C90001 The License Is About To Expire
- 0xF0C90002 The License Has Expired
- 0xF0C90006 The System Has Entered Safe Mode
- 0xF0CE0001 Failed To Monitor A Disk Enclosure
- 0xF0CE0002 Disk Enclosure Quantity Exceeds The System Limit
- 0xF0CE0005 Disk Enclosure Temperature Exceeds The Upper Limit
- 0xF0CE0007 Engine Or Disk Enclosure Temperature Is Below The Lower Limit
- 0xF0CE0008 Controller Enclosure Temperature Exceeds The Upper Limit
- 0xF0CE0009 Controller Enclosure Temperature Is Far Beyond The Upper Limit
- 0xF0CE000A Disk Enclosure Temperature Is Far Beyond The Upper Limit
- 0xF0CF0005 Abnormal Communication Between Controllers
- 0xF0CF0006 Controller Is Removed
- 0xF0D10005 Interface Module Is Removed
- 0xF0D10008 Interface Module Is Unrecognizable
- 0xF0D10009 Interface Module Temperature Exceeds The Upper Limit
- 0xF0D20004 BBU Module Is Removed
- 0xF0D20005 BBU Module Temperature Exceeds The Upper Limit
- 0xF0D30003 Fan Module Is Removed
- 0xF0D80002 Storage Pool Is Abnormal
- 0xF0DD0001 Remote Replication Consistency Group Is Disconnected
- 0xF0DD0002 Remote Replication Consistency Group Is Unavailable
- 0xF0DD0004 Remote Replication Consistency Group Is Automatically Split
- 0xF0EA0003 Port Optical Module Is Faulty
- 0xF0EA0004 Port Unavailable Due To Incompatible Optical Module Type
- 0xF0EA0005 Optical Module Rate Is Inconsistent With That Of Its Port
- 0xF3C010001 HyperMetro Is Unavailable
- 0xF3C010002 The Host Has An Incorrect Access Permission
- 0xF3C010005 One Storage Array Of A HyperMetro Consistency Group Is Isolated
- 0xF3C010006 One Storage Array Of A HyperMetro Pair Is Isolated
- 0xF3C010009 HyperMetro Arbitration Information Conflicts With The Existing Information
- 0xF3C01000E The HyperMetro Pair Is Interrupted And The Local LUN Cannot Provide Services
- 0xF3C01000F The HyperMetro Pair Is Interrupted And The Local LUN Continues To Provide Services
- 0xF3C010010 The HyperMetro Consistency Group Is Disconnected And Member LUNs In The Local Consistency Group Cannot Provide Services
- 0xF3C010011 The HyperMetro Consistency Group Is Disconnected And Member LUNs In The Local Consistency Group Continue To Provide Services
- 0xF3C020000 The HyperMetro Domain Is Unavailable
- 0xF3C030002 No Backup Links Available
- 0xF3C030004 Quorum Server Is Disconnected From The Storage Array
- 0xF3C040002 HyperMetro Consistency Group Is Unavailable
- 0xF3C040003 The Host Has An Incorrect Access Permission For HyperMetro Consistency Group
- 0xF3C040004 The HyperMetro Consistency Group Arbitration Information Conflicts With The Existing Information
- 0xF50000001 A Certificate Has Expired
- 0xF50000002 A Certificate Is About To Expire
- 0xF50000005 A Certificate Revocation List Has Expired
- 0xF50000007 A CA Certificate Is About To Expire
- 0xF50000008 A CA Certificate Has Expired
- 0xFD0008 LUN Migration Is Faulty
- 0xFE05B0003 EService Failed To Connect To The Remote Server
- 0xFE0A40002 DR Star Is Invalid
- 0xFF0F00D10038 The Link Between An Interface Module And A Controller Is Abnormal
- 0xF00DD0005 Remote Replication Consistency Group Is Disconnected
- 0xF00710007 The SMTP Server For Receiving Two-Factor Authentication Information Is Unavailable
- 0xF000B0117 FC Link Of Heterogeneous Array Disconnected
How to Obtain Help
- Glossary
- Acronyms and Abbreviations