0xF0CF0005 Abnormal Communication Between Controllers
0xF0CF0005 Abnormal Communication Between Controllers
Description
The communication between controllers in a controller enclosure is abnormal.
Applicable Model
Applicable to all models.
Attribute
ID
Event Type
Event Level
Automatically Cleared
0xF0CF0005
Alarm
Major
Yes
Impact on the System
The normal operation of the storage system is not affected.
Possible Causes
Controller components are faulty.
Backplane components are faulty.
Heartbeat connections are down.
Mirror links are down.
Mirror links have too many bit errors.
Procedure
Check whether any controller that encounters a communication error is being restarted or powered off.
If yes, wait until the controller is restarted or powered on. If the alarm persists=> Step2.