0xF00CF0084 Heat Dissipation System Of The Controller Is Faulty
0xF00CF0084 Heat Dissipation System Of The Controller Is Faulty
Description
The heat dissipation system of the controller cannot work properly.
Applicable Model
Applicable to all models.
Attribute
ID
Event Type
Event Level
Automatically Cleared
0xF00CF0084
Alarm
Major
Yes
Impact on the System
The temperature of the controller may exceed the upper limit and the controller enters the power-off protection mode.
Possible Causes
Fan modules on the controller are faulty.
Procedure
Replace the faulty fans according to the location information in the alarm. Ensure that all the faulty fans are replaced. If the alarm persists=> Step2.
Collect related information and contact technical support engineers.