0xF00CF007F The Controller Power-on Times Out
Applicable Model
Applicable to all models.
Impact on the System
- The controller power-on times out. System reliability decreases.
- With the write protection function being enabled (by default) when an engine works with a single controller, if the controller that fails to be initiated cannot return to normal within the specified period, the write function of services on the engine where the faulty node resides is disabled and the read performance is reduced.
Procedure
- Collect the log information and contact technical support engineers to rectify the fault. If the fault cannot be rectified immediately=> Step2.
- The system enters the write protection status after a while. The system does not provide write services and read performance decreases. If you want to restore system performance, enter the developer view of CLI and run the "change system write_policy write_protect_switch=Disable" command to disable the single-controller write protection function. However, if the controller malfunctions after the function is disabled, data may be lost, affecting system reliability.