No relevant resource is found in the selected language.
Your browser version is too early. Some functions of the website may be unavailable. To obtain better user experience, upgrade the browser to the latest version.
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00CE002A Disk Enclosure Is Working In Single Link State
0xF00CE002A Disk Enclosure Is Working In Single Link State
Description
A disk enclosure is working in single-link state.
Applicable Model
Applicable to all models.
Attribute
ID
Event Type
Event Level
Automatically Cleared
0xF00CE002A
Alarm
Major
Yes
Impact on the System
A disk enclosure working in single-link state may go offline.
Possible Causes
Expansion cables are incorrectly connected or removed.
Expansion modules are incorrectly inserted or removed.
Expansion cables are damaged.
Expansion modules are faulty.
Procedure
Check the expansion module and expansion cable.
If the expansion module or expansion cable is removed, reinsert the expansion cable or expansion module. If the alarm persists=> 1.2.
Replace the expansion cable. If the alarm persists=> 1.3.
Replace the expansion module. If the alarm persists=> Step2.
Collect related information and contact technical support engineers.