0xF00E00049 The Replication Link Between The Storage Array And The Interface Module Of The Remote Device Does Not Meet The Redundancy Requirements
Description
The replication link between the storage array and the interface module of the remote device does not meet the redundancy requirements.
Applicable Model
Applicable to all models.
Impact on the System
The reliability of the remote replication or HyperMetro feature decreases. In the system upgrade or some fault scenarios, the remote replication or HyperMetro service may be interrupted.
Possible Causes
- The interface modules of the replication link between the storage array and the remote device are not from the upper and lower layers of the controller enclosure.
- The interface module is faulty.
Procedure
- Check whether cable connections between the storage array and ports on the remote device meet redundancy requirements. (The ports are from different interface modules, and the interface modules are from the upper and lower layers of the controller enclosure.)
- Check whether the interface module of the remote device connected to the storage array is working properly and go to => Step3.
- Collect related information and contact technical support engineers.