0xF01320004 The System Failed To Monitor Assistant Cooling Unit
0xF01320004 The System Failed To Monitor Assistant Cooling Unit
Description
The assistant cooling unit hardware is faulty, or the communication links between the assistant cooling unit and controller are faulty.
Applicable Model
Applicable to all models.
Attribute
ID
Event Type
Event Level
Automatically Cleared
0xF01320004
Alarm
Major
Yes
Impact on the System
The system temperature may rise, which may affect system running.
The storage I/O performance may decrease.
Possible Causes
The assistant cooling unit is faulty.
The communication links between the assistant cooling unit and controller are faulty.
Procedure
Replace the faulty assistant cooling unit. If the alarm persists=> Step2.
Replace the controller vertically corresponding to the faulty assistant cooling unit. If the alarm persists=> Step3.
Collect related event information, and contact technical support engineers for assistance.