Configuration Planning
Before migrating data, make network and service plans to facilitate subsequent operations.
Network Planning
According to the requirement analysis, the OceanStor Dorado 6000 V6 is used to take over LUNs created on the HDS USP-V and the S5600T. Before configuring data migration, the customer needs to connect the OceanStor Dorado 6000 V6 to the existing network. Figure 4-2 shows the transformed network.
Table 4-5 lists the zones created to ensure normal communication among storage systems and the application server.
Service Planning
From the conclusions of the requirement analysis, it can be inferred that the enterprise uses SmartVirtualization and SmartMigration to migrate data. Figure 4-3 illustrates the configuration roadmap.
Table 4-6 describes the configuration operations and plan items.
Configuration Roadmap |
Major Operation and Purpose |
Plan Item |
GUI Parameter |
Planned Value |
---|---|---|---|---|
Change the network. |
Connect the OceanStor Dorado 6000 V6 to the existing network. |
None |
None |
None |
Create zones on the Fibre Channel switch. |
Zone names and nodes included in each zone |
None |
Planned based on Table 4-5 |
|
Create target LUNs for the data migration |
On the S5600T, create two LUNs to act as target LUNs for the data migration. |
|
|
NOTE:
To meet future data growth needs, it is recommended that the capacities of the target LUNs be larger than the original LUNs on the HDS USP-V. |
Set up a logical connection between storage systems. |
Set up a logical connection between the OceanStor Dorado 6000 V6 and the HDS USP-V. NOTE:
|
None |
None |
None |
Set up a logical connection between the OceanStor Dorado 6000 V6 and the S5600T. NOTE:
After the OceanStor Dorado 6000 V6 is connected to the S5600T, the S5600T identifies the OceanStor Dorado 6000 V6 as a host. |
|
|
|
|
Enable the OceanStor Dorado 6000 V6 to host LUNs created on the original storage systems. |
Use the OceanStor Dorado 6000 V6 to host LUNs created on the HDS USP-V, and create eDevLUNs corresponding to these LUNs. |
|
|
|
Use the OceanStor Dorado 6000 V6 to host LUNs created on the S5600T, and create eDevLUNs corresponding to these LUNs. |
|
|
|
|
Stop services running on the HDS USP-V. |
Delete the HDLM multipathing software delivered with the HDS USP-V. |
None |
None |
None |
Close the database. |
None |
None |
None |
|
Remove the AIX-based application server and the HDS USP-V from their joint zone. |
None |
None |
None |
|
Enable the OceanStor Dorado 6000 V6 to take over services. |
Install OceanStor UltraPath. |
Version of OceanStor UltraPath to be installed |
None |
None |
Set up a mapping relationship between the AIX-based application server and the eDevLUNs corresponding to LUNs created on the HDS USP-V. |
|
|
|
|
Scan for LUNs on the AIX-based application server. |
None |
None |
None |
|
Use SmartMigration to set up a data migration relationship. |
Configure SmartMigration. |
|
|
|
Stop services running on the OceanStor Dorado 6000 V6. |
Close the database. |
None |
None |
None |
Remove the OceanStor Dorado 6000 V6 and the AIX-based application server from their joint zone. |
None |
None |
None |
|
Enable the S5600T to take over services. |
Set up a mapping relationship between the AIX-based application server and the target LUNs created on the S5600T. |
|
|
|
Scan for LUNs on the AIX-based application server. |
None |
None |
None |
|
a: The description in the brackets after a parameter indicates the object of the parameter. |