Table 2-7 Drive configuration
Configuration
Maximum Front Drives
Maximum Rear Drives
Drive Management Mode
25 x 2.5" drive EXP configuration[1]
25 (SAS/SATA drives)
I/O module 1: 2 SAS/SATA drives
I/O module 3[2]: 4 (NVMe drives)
SAS/SATA drive: 1 x screw-in RAID controller card
NVMe drive: directly connected to the CPU
12 x 3.5" drive EXP configuration[1]
12 (SAS/SATA drives)
I/O module 1: 2 SAS/SATA drives
I/O module 2: 2 (SAS/SATA drives)
I/O module 3[2]: 4 (NVMe drives)
SAS/SATA drive: 1 x screw-in RAID controller card
NVMe drive: directly connected to the CPU
12 x 3.5" drive pass-through configuration[1, 3]
12 (SAS/SATA drives)
I/O module 2: 2 (SAS/SATA drives)
I/O module 3[2]: 4 (NVMe drives)
SAS/SATA drives: SAS directly connected to the CPU
NVMe drive: directly connected to the CPU
8 x 2.5" SAS/SATA + 12 x 2.5" NVMe drive configuration[1]
20
Slots 0 to 7 support only SAS and SATA drives.
Slots 8 to 19 support only NVMe drives.[4]
I/O module 3[2]: 4 (NVMe drives)
SAS/SATA drive: 1 x screw-in RAID controller card
NVMe drive: directly connected to the CPU
24 x 2.5" drive pass-through configuration[1, 5]
24 SAS/SATA drives
I/O module 3[2]: 4 (NVMe drives)
SAS/SATA drives: SAS directly connected to the CPU
NVMe drive: directly connected to the CPU
8 x 2.5" drive configuration[1, 5]
8 (SAS/SATA drives)
I/O module 3[2]: 4 (NVMe drives)
SAS/SATA drive: 1 x screw-in RAID controller card
NVMe drive: directly connected to the CPU
[1]: The server with 24 x 2.5" drive pass-through configuration, 8 x 2.5" drive configuration, 25 x 2.5" drive EXP configuration, or 8 x 2.5" SAS/SATA + 12 x 2.5" NVMe drive configuration support only 2.5" front drives. The server with 12 x 3.5" drive EXP configuration or with 12 x 3.5" drive pass-through configuration supports only 3.5" front drives.
[2]: I/O module 3 supports 2.5" drives, and I/O modules 1 and 2 support 2.5" and 3.5" drives.
[3]: CPU SAS pass-through requires a SAS riser card. By default, it is installed on I/O module 2.
[4]: The NVMe drives in slots 8 to 19 of the server configured with 8 x 2.5" SAS/SATA + 12 x 2.5" NVMe drives support only PCIe 3.0.
[5]: When powered by Kunpeng 920 5220 or 3210 processors, the server does not support 24 x 2.5" SAS/SATA pass-through drive configuration.