Sensor List (Server Configured with the Kunpeng 920 5220 or 3210 Processors)
Sensor |
Description |
Component |
---|---|---|
Inlet Temp |
Air inlet temperature |
Right mounting ear |
Outlet Temp |
Air outlet temperature |
iBMC card |
CPUN Core Rem |
CPU core temperature |
CPU. N indicates the CPU number. The value is 1 or 2. |
CPUN Prochot |
CPU Prochot |
|
CPUN VDDQ Temp |
CPU VDDQ temperature |
CPU 1: components in position U1 on the mainboard. CPU 2: components in position U2 on the mainboard. N indicates the CPU number. The value is 1 or 2. |
CPUN VRD Temp |
CPU VRD temperature |
CPU 1: components in position U1 on the mainboard. CPU 2: components in position U2 on the mainboard. N indicates the CPU number. The value is 1 or 2. |
CPUN MEM Temp |
CPU DIMM temperature |
DIMMs of CPUN. N indicates the CPU number. The value is 1 or 2. |
Disks Temp |
Highest temperature among the temperatures of all drives |
- |
FANN Speed |
Fan speed |
Fan module. N indicates the fan module number. The value ranges from 1 to 4. |
Power |
Server input power |
Total power of all the PSUs. |
PowerN |
PSU input power |
PSU. N indicates the PSU number. The value is 1 or 2. |
CPUN Status |
CPU status |
CPU. N indicates the CPU number. The value is 1 or 2. |
CPUN Memory |
DIMM status |
DIMMs of CPUN. N indicates the DIMM number. The value is 1 or 2. |
PSN Fan Status |
PSU fan fault status |
PSU. N indicates the PSU number. The value is 1 or 2. |
PSN Temp Status |
PSU presence status |
|
PSN Status |
PSU fault status |
|
Power Button |
Power button pressed |
Right mounting ear |
UID Button |
UID button status |
|
DISKN |
Drive status |
Drive. N indicates the physical drive slot number. |
FANN Presence |
Fan presence |
Fan module. N indicates the fan module number. The value ranges from 1 to 4. |
FANN Status |
Fan fault status |
|
RTC Battery |
RTC battery status. An alarm is generated when the voltage is lower than 1 V. |
CMOS battery |
DIMMN |
DIMM status |
DIMM. N indicates the DIMM slot number. |
PSN Inlet Temp |
PSU air inlet temperature |
PSU. N indicates the PSU number. The value is 1 or 2. |
PS Redundancy |
Redundancy failure alarm due to PSU removal |
PSU |
BMC Boot Up |
BMC startup event |
N/A. N indicates the component number. |
SEL Status |
Event of SEL being about to be full or being cleared |
|
Op. Log Full |
Event of operation logs being about to be full or being cleared |
|
Sec. Log Full |
Event of security logs being about to be full or being cleared |
|
CPU Usage |
CPU usage |
|
Memory Usage |
Memory usage |
|
BMC Time Hopping |
Time hopping |
|
NTP Sync Failed |
Event of NTP synchronization failure and recovery |
|
Host Loss |
System monitoring software (BMA) link loss detection |
|
SYS 12V_1 |
Mainboard 12.0 V voltage (the second output 12 V voltage detection for soft-start: fan module) |
|
SYS 12V_2 |
Mainboard 12.0 V voltage (the third output 12 V voltage detection for soft-start: CPU 2 + rear-drive backplane) |
|
SYS 12V_3 |
Mainboard 12.0 V voltage (the fourth output 12 V voltage detection for soft-start: CPU 1 + CPU2) |
|
SYS 12V_4 |
Mainboard 12.0 V voltage (the fifth output 12 V voltage detection for soft-start: front-drive backplane) |
|
SYS 12V_5 |
Mainboard 12.0 V voltage (the sixth output 12 V voltage detection for soft-start: NIC + riser card + RAID controller card + rear-drive backplane) |
|
CPUN VDDQ_AB |
CPU memory voltage |
|
CPUN VDDQ_CD |
||
CPUN VRD Temp |
CPU VRD voltage |
|
CPUN VDDAVS |
CPU VDDAVS voltage |
|
CPUN VDDFIX |
CPU VDDFIX voltage |
|
SAS Cable |
Entity presence |
|
PSN VIN |
Input voltage |
|
PwrOk Sig. Drop |
Voltage dip status |
|
ACPI State |
ACPI status |
|
SysFWProgress |
Software process and system startup errors |
|
SysRestart |
System restart cause |
|
Boot Error |
Boot error |
|
Watchdog2 |
Watchdog |
|
Mngmnt Health |
Management subsystem health status |
|
RiserN Card |
Entity presence |
|
RAID Presence |
RAID controller card presence |
|
RAID Temp |
RAID controller card temperature |
|
PCIe Status |
PCIe status |
|
PwrOn TimeOut |
Power-on timeout |
|
PwrCap Status |
Power capping status |
|
HDD Backplane |
Drive backplane entity presence |
|
HDD BP Status |
Drive backplane health status |
|
NICN Temp |
NIC temperature |
|
NIC OM Temp |
NIC OM temperature |
|
NIC1-N Link Down (N 1. 2. 3. 4) |
Network port link status of NIC 1 |
|
NIC2-N Link Down (N 1. 2. 3. 4) |
Network port link status of NIC 2 |
|
System Notice |
Hot restart reminder and fault diagnosis program information collection |
|
System Error |
System suspension or restart. Check the background logs. |
|
Cert OverDue |
Certificate expiration check |
|
RTC time |
RTC clock status |