Installing the Avago SAS3004iMR PCIe RAID Control Card
Procedure
- Power off the server.
For details, see Power-Off Procedure.
- Remove the power cables from the PSUs.
For details, see Removing PSU Cables.
- Remove the server.
For details, see Removing the Server.
- Place the server on the ESD workstation.
- Remove the chassis cover.
For details, see Removing the Chassis Cover.
- Take the spare part out of its ESD bag.
- Determine the position of the Avago SAS3004iMR RAID controller card.
- Remove the PCIe riser modules.
For details, see Removing a PCIe Riser Module.
- Install the Avago SAS3004iMR RAID controller card.
For details, see Installing a PCIe Card.
- Install the PCIe riser modules.
For details, see Installing a PCIe Riser Module.
- Install the M.2 FRU on the Avago SAS3004iMR RAID controller card.
For details, seeInstalling an M.2 FRU on the Avago SAS3004iMR PCIe RAID Controller Card .
- Install the chassis cover.
For details, see Installing the Chassis Cover.
- Install the server.
For details, see Installing a Server.
- Connect the power cables to the PSUs.
For details, see Connecting PSU Cables.
- Power on the server.
For details, see Power-On Procedure.
- Log in to the iBMC WebUI, and check whether the new component is normal.
For details, see Atlas 800 Inference Server iBMC User Guide (Model 3010).