Installing an M.2 FRU on the Avago SAS3004iMR PCIe RAID Controller Card
The M.2 FRU on the Avago SAS3004iMR RAID controller card is hot swappable.
Procedure
- Determine the positions and slots of the M.2 FRUs on the Avago SAS3004iMR RAID controller card.Figure 6-88 Positions and slots of the M.2 FRUs
- Remove the M.2 FRU filler module.
Perform this step only when you configure an M.2 FRU filler module.
- Install an M.2 FRU on the Avago SAS3004iMR PCIe RAID controller card.
- Take a spare M.2 FRU out of its ESD bag.
- Open the handle of the M.2 FRU and push the M.2 FRU into the slot of the Avago SAS3004iMR RAID control card. See (1) in Figure 6-89.
- Close the handle of the M.2 FRU. See (2) in Figure 6-89.
- Check the status of the M.2 FRU indicator on the Avago SAS3004iMR RAID controller card.Figure 6-90 M.2 FRU indicatorsTable 6-7 Indicator status
Indicator
Description
M.2 FRU fault indicator
- Off: The M.2 FRU is running properly.
- Blinking yellow: The M.2 FRU is being located, or RAID is being rebuilt.
- Steady yellow: The M.2 FRU is faulty or not detected.
M.2 FRU activity indicator
- Off: The M.2 FRU is not in position or is faulty.
- Blinking green: Data is being read, written, or synchronized.
- Steady green: The M.2 FRU is inactive.