Table 4-2 lists the requirements for the hardware application environment of the Atlas 300I inference card (model 3000).
Table 4-2 Atlas 300I inference card (model 3000) hardware application environmental conditionsItem
|
Specification
|
Temperature
|
- Operating temperature: 0°C to 55°C (32°F to 131°F)
- Storage temperature: -40°C to +75°C (-40°F to +167°F)
|
Humidity
|
- Operating humidity: 5% RH to 90% RH (non-condensing)
- Storage humidity: 5% RH to 95% RH (non-condensing)
|
Maximum altitude
|
3000 m (9842.4 ft.) For altitudes above 900 m (2952.72 ft.), the highest operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft.) in altitude.
NOTE: ASHRAE 2015 compliant:
- When the server complying with ASHRAE Classes A1 and A2 is used in the altitude of above 900 m (2952.76 ft), the highest operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.25 ft).
- When the server complying with ASHRAE Class A3 is used in the altitude of above 900 m (2952.76 ft), the highest operating temperature decreases by 1°C (1.8°F) for every increase of 175 m (574.15 ft).
- When the server complying with ASHRAE Class A4 is used in the altitude of above 900 m (2952.76 ft), the highest operating temperature decreases by 1°C (1.8°F) for every increase of 125 m (410.10 ft).
|