Adding Controllers Using SmartKit
This section describes how to use the expansion tool to add controllers.
For details about how to add controllers in different scenarios, see Table 11-8.
Scenario |
Reference Section |
---|---|
Expanding 2 controllers to 6, 8, 10, and 12 controllers |
|
Expanding 4 controllers to 6, 8, 10, and 12 controllers |
|
Expanding 6 to 10 or 12 controllers |
|
Expanding 8 controllers to 10 or 12 controllers |
Expanding 2 Controllers to 6 or More Controllers
This section describes how to use SmartKit to add controllers.
Prerequisites
- C versions of the controller enclosures to be added for expansion and the original storage system are consistent. Otherwise, upgrade the controller software of the earlier version. For specific upgrade methods, refer to Upgrade Guide of the target version.
- The memory size of the controllers to be added for expansion is the same as that of the original storage system.
- Controller enclosures to be added have been powered on.
- The network has been deployed based on the scenario.
- There is no critical or major alarm in the storage system.
- The IP addresses of the management network ports on controller enclosures connected to the management network must be different. For details, see section "Changing IP Addresses of Management Network Ports" in the Installation Guide.
Precautions
- SmartKit is used to expand controllers for the storage system.
- The operation procedure varies with the SmartKit version. The actual GUI prevails.
- For controller enclosure 0, ensure that no Ethernet NICs are installed in slots IOM H9/L9 to IOM H13/L13. If Ethernet NICs have been installed in these slots, remove the Ethernet NICs before controller expansion and insert them back after controller expansion. Otherwise, the Ethernet NICs cannot be used after controller expansion.
Procedure
- Open SmartKit.
- Add the storage device whose capacity is to be expanded to SmartKit.
- In the main window of SmartKit, click the Devices tab and select Add.
The dialog box for adding devices is displayed.
- In Basic Information, select Specify IP Address (add a device by the IP address) and enter the management IP address of the original storage system. Then click Next.
- In the Login Information area, enter the user name and password of the storage system super administrator and click Finish.
- When a device is added for the first time or a device certificate is not trusted, a message is displayed indicating that the connection is not trusted.
- When an SSH server is added for the first time or the fingerprint of an SSH server changes, a message is displayed asking whether you want to continue to register the SSH server.
- In the main window of SmartKit, click the Devices tab and select Add.
- In the main window of SmartKit, choose Home > Storage > Capacity Expansion > Add Controllers.
The Add Controllers page is displayed.
- Select devices.
- Click Device Selection. The Select Devices dialog box is displayed.
- Select the storage system for which you want to expand controllers and the results save folder and click OK.
- Ensure compliance with the safety operation guide.
- Click Safety Operation Guide. The Safety Operation Guide dialog box is displayed.
- Make sure that the prerequisites displayed on the user interface have been prepared. Select the prerequisites and click OK.
- Evaluate the capacity expansion solution.
- Click Expansion Evaluation.
The Expansion Configuration page is displayed.
- (Optional) For devices that are configured with HyperMetro, select the device you want to perform capacity expansion evaluation from the device list and click Next.
- Select a capacity expansion scenario.
Select Add controllers in Capacity expansion scenario. Select the number of controllers after the capacity expansion, and enter the BOM codes of the new enclosure by referring to the BOQ for capacity expansion. Use commas (,) to separate multiple BOM codes.
- Click Add Hardware Information and Expansion Mode.
You can add multiple configuration policies.
- Specify the configuration parameters according to the capacity expansion plan. Table 11-9 lists the parameters.
Table 11-9 Capacity evaluation parameters
Parameter
Description
Storage Capacity Expansion Mode
Method to add storage space.
BOM of Disk
BOM code of the new disk.
NOTE:- If the BOM code of the new disk is the same as an existing one in the storage system, select the BOM code from the drop-down list.
- If the BOM code of the new disk is not included in the drop-down list box, select Customize.
- To add multiple disk types, click Add Hardware Information and Expansion Mode to add new configuration policies.
Disk Type
Type of the new disks.
NOTE:- When Customize is selected for BOM of Disk, you need to manually select a disk type.
- Self-encrypting drives (SEDs) are supported.
Physical Capacity of a Single Disk
Capacity of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually enter the disk capacity.
Capacity Unit
Capacity unit of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually select a capacity unit.
Disk Quantity
Number of new disks.
Operation
You can click Delete to delete the current configuration policy.
- Click Next.
The Information page is displayed.
- Read and confirm the displayed message, and click OK.
The Start Evaluation page is displayed and the system starts evaluating the capacity expansion solution.
- After the evaluation is complete, click Open the report to go to the save path of the evaluation report. The report is a .zip file named by the evaluation time.
- You can also click View the report to open the report directly.
- Click Finish.
Rectify the failed items (if any) according to the suggestions and evaluate the solution again. If the items fail again, contact Huawei technical support engineers for assistance. Otherwise, risks may arise during capacity expansion.
- Click Expansion Evaluation.
- Open the Add Controller Wizard dialog box.
- Click Expansion.
The Expansion page is displayed.
- Select Add Controller.
The Select Expansion Mode dialog box is displayed.
- Select Networking Mode and Configuration after expansion.
Set Networking Mode to Switch-based network and Configuration to the number of controllers after expansion.
- Click OK.
The Add Controller Wizard dialog box is displayed.
- Click Expansion.
- Add controllers as prompted by the wizard.
- Confirm the precautions of SmartKit.
- If the expansion engine has been unpacked before or has been powered on before, perform operations in Clearing Configuration Information About Controllers to Be Added.
- Ensure that the AD process has been enabled. For details, see Enabling the AD Process for New Controllers.
Select I have read the previous precautions, completed the related operations, and understood consequences of the operation and click Next.
The Confirm Specifications of Controllers Being Added page is displayed.
- Confirm the expansion-related specifications.
This step applies only to the scenario two controllers are expanded to six or ten controllers, and the 4 U controller enclosure to be added contains four controllers. Otherwise, skip this step, select precautions, and click Next.
If the environment has four controllers in a 4 U controller enclosure, follow instructions in Restoring Dual-controller configuration for processing.
After confirmation, select I have confirmed the information and understood the consequences associated with performing this operation and click Next.
The Check Before Capacity Expansion page is displayed.
- The system automatically checks the expansion condition.
If any check item fails, rectify the faults and perform the check again.
After all check items are passed, click Next.
If the item The IBC public/private key pair is the default one is not passed, see How Can I Restore the IBC Public/Private Key Pair to the Default Value?
The Complete Networking page is displayed.
- The system automatically modifies the expansion configuration.
A dialog box is displayed when the system automatically adds controllers. Install controllers by referring to How Do I Install New Controllers in a Controller Enclosure?. Confirm the information in the dialog box, select I have confirmed the preceding information and inserted the controllers to be added, and click OK. The system continues to add controllers.
If any expansion item is paused unexpectedly, a fault occurs during the expansion. Rectify the fault according to the suggestions provided by SmartKit and then click Re-Execute. If the item is paused again, the fault still exists. In this situation, refer to What Can I Do When SmartKit Pauses Unexpectedly in Adding Controllers to a 4 U Controller Enclosure?
After modification, click Next.
The Post-expansion Check page is displayed.
- The system automatically performs a post-expansion check.
If the check fails, rectify the faults and click Recheck to perform the check again.
After all check items are passed, click Next.
The Obtain Cluster Information page is displayed.
- The system automatically obtains the cluster information.
After the cluster information has been obtained, click Next.
The Confirm the Networking Environment page is displayed.
- Confirm the network environment and configure data switches.
- Click the network diagram to obtain the network diagram.
It is recommended that you connect the cables according to the networking diagram in this document. Other networking may cause controller expansion failure.
- Ensure that cables are properly connected according to the network diagram.
Select I have read the previous information and understood consequences of the operation and click Next.
The Configure Data Switch page is displayed.
- Enter the configuration information about the data switch, as described in Table 11-10.
Table 11-10 Data switch parameters
Parameter
Description
Data switch 0 Management IP Address
IP address of the management network port on data switch 0.
Data switch 0 Username
User name used to log in to data switch 0 through SSH. For details about the user name, see Configuring New IP Addresses for the Management Network Ports on the Switches and SSH Login User Information.
Data switch 0 Password
Password used to log in to data switch 0 through SSH.
Data switch 0 SSH Port
Port used to log in to data switch 0 through SSH. The default port is port 22.
Data switch 1 Management IP Address
IP address of the management network port on data switch 1.
Data switch 1 Username
User name used to log in to data switch 1 through SSH. For details about the user name, see Configuring New IP Addresses for the Management Network Ports on the Switches and SSH Login User Information.
Data switch 1 Password
Password used to log in to data switch 1 through SSH.
Data switch 1 SSH Port
Port used to log in to data switch 1 through SSH. The default port is port 22.
- Before configuring the data switch, ensure that no other user has logged in or is using the switch. Otherwise, the configuration operation will fail.
- If you need to manually configure data switches, complete the configuration by referring to (Optional) Manually Configuring Switches (CE8850-32CQ-EI) and click Cancel.
After configuration, click OK.
The Scan for Node Information page is displayed.
- Click the network diagram to obtain the network diagram.
- The system automatically detects node information. If the system fails to detect the information of the new controllers, rectify the faults as prompted and click Rescan.
After the system obtains the node information, confirm and select the controller enclosure to be expanded based on Controller enclosure SN.
After confirming all controller enclosures, select I have read the previous information and understood consequences of the operation and click Next.
The Check the Added Controller page is displayed.
You can query the SN of a controller enclosure on the label on its exterior, for example, 2102XXXXXXXXE700000X.
- The system automatically checks the network connection.
If the network connection check fails, reconnect the network and click Recheck.
After the check passes, click Next.
The Capacity Expansion page is displayed.
- The system automatically starts adding controllers.
If either of the following issues occurs, refer to What Can I Do When an Exception Occurs in Using SmartKit to Add a New Controller Enclosure?
- If any expansion item fails and the system reports "The communication is abnormal or the system is busy", the connection between SmartKit and the storage system is interrupted.
- If any expansion item is paused unexpectedly, a fault occurs during the expansion. Rectify the fault according to the suggestions provided by SmartKit and then click Re-Execute. If the item is paused again, the fault still exists.
After the controllers are successfully added, click Next.
The Post-expansion Check page is displayed.
- The system automatically performs a post-expansion check.
If the check fails, identify and rectify the failed items. Then click Recheck to perform the check again.
After all check items are passed, click Next.
The Completed page is displayed.
- Click Finish to complete the expansion.
- Confirm the precautions of SmartKit.
- Inspect the system after expansion.
- Click Post-Expansion Inspection. The inspection tool page is displayed.
- Click Select Check Items.
In the check item list, select the items you want to check.
- Click Next to start the inspection.
- Open the result directory is linked to the directory that stores the inspection report.
- View the report is linked to the inspection results that are saved as .html files. These files are also compressed and stored in the result directory.
- Click Finish. The inspection is complete.
Expanding 4 Controllers to 6 or More Controllers
This section describes how to use SmartKit to add controllers.
Prerequisites
- C versions of the controller enclosures to be added for expansion and the original storage system are consistent. Otherwise, upgrade the controller software of the earlier version. For specific upgrade methods, refer to Upgrade Guide of the target version.
- The memory size of the controllers to be added for expansion is the same as that of the original storage system.
- Controller enclosures to be added have been powered on.
- The network has been deployed based on the scenario.
- There is no critical or major alarm in the storage system.
- The IP addresses of the management network ports on controller enclosures connected to the management network must be different. For details, see section "Changing IP Addresses of Management Network Ports" in the Installation Guide.
Precautions
- SmartKit is used to expand controllers for the storage system.
- The operation procedure varies with the SmartKit version. The actual GUI prevails.
Procedure
- Open SmartKit.
- Add the storage device whose capacity is to be expanded to SmartKit.
- In the main window of SmartKit, click the Devices tab and select Add.
The dialog box for adding devices is displayed.
- In Basic Information, select Specify IP Address (add a device by the IP address) and enter the management IP address of the original storage system. Then click Next.
- In the Login Information area, enter the user name and password of the storage system super administrator and click Finish.
- When a device is added for the first time or a device certificate is not trusted, a message is displayed indicating that the connection is not trusted.
- When an SSH server is added for the first time or the fingerprint of an SSH server changes, a message is displayed asking whether you want to continue to register the SSH server.
- In the main window of SmartKit, click the Devices tab and select Add.
- In the main window of SmartKit, choose Home > Capacity Expansion > Add Controllers.
The Add Controllers page is displayed.
- Select devices.
- Click Device Selection. The Select Devices dialog box is displayed.
- Select the storage system for which you want to expand controllers and the results save folder and click OK.
- Ensure compliance with the safety operation guide.
- Click Safety Operation Guide. The Safety Operation Guide dialog box is displayed.
- Make sure that the prerequisites displayed on the user interface have been prepared. Select the prerequisites and click Confirm.
- Evaluate the capacity expansion solution.
- Click Expansion Evaluation.
The Expansion Configuration page is displayed.
- (Optional) For devices that are configured with HyperMetro, select the device you want to perform capacity expansion evaluation from the device list and click Next.
- Select a capacity expansion scenario.
Select Add controllers in Capacity expansion scenario. Select the number of controllers after the capacity expansion, and enter the BOM codes of the new enclosure by referring to the BOQ for capacity expansion. Use commas (,) to separate multiple BOM codes.
- Click Add Hardware Information and Expansion Mode.
You can add multiple configuration policies.
- Specify the configuration parameters according to the capacity expansion plan. Table 11-11 lists the parameters.
Table 11-11 Capacity evaluation parameters
Parameter
Description
Storage Capacity Expansion Mode
Method to add storage space.
BOM of Disk
BOM code of the new disk.
NOTE:- If the BOM code of the new disk is the same as an existing one in the storage system, select the BOM code from the drop-down list.
- If the BOM code of the new disk is not included in the drop-down list box, select Customize.
- To add multiple disk types, click Add Hardware Information and Expansion Mode to add new configuration policies.
Disk Type
Type of the new disks.
NOTE:- When Customize is selected for BOM of Disk, you need to manually select a disk type.
- Self-encrypting drives (SEDs) are supported.
Physical Capacity of a Single Disk
Capacity of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually enter the disk capacity.
Capacity Unit
Capacity unit of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually select a capacity unit.
Disk Quantity
Number of new disks.
Operation
You can click Delete to delete the current configuration policy.
- Click Next.
The Information page is displayed.
- Read and confirm the displayed message, and click OK.
The Start Evaluation page is displayed and the system starts evaluating the capacity expansion solution.
- After the evaluation is complete, click Open the report to go to the save path of the evaluation report. The report is a .zip file named by the evaluation time.
- You can also click View the report to open the report directly.
- Click Finish.
Rectify the failed items (if any) according to the suggestions and evaluate the solution again. If the items fail again, contact Huawei technical support engineers for assistance. Otherwise, risks may arise during capacity expansion.
- Click Expansion Evaluation.
- Open the Add Controller Wizard dialog box.
- Click Expansion.
The Expansion page is displayed.
- Select Add Controller.
The Select Expansion Mode dialog box is displayed.
- Select Networking Mode and Configuration after expansion.
Set Networking Mode to Switch-based network and Configuration to the number of controllers after expansion.
- Click OK.
The Add Controller Wizard dialog box is displayed.
- Click Expansion.
- Add controllers as prompted by the wizard.
- Confirm the precautions of SmartKit.
- If the expansion engine has been unpacked before or has been powered on before, perform operations in Clearing Configuration Information About Controllers to Be Added.
- Ensure that the AD process has been enabled. For details, see Enabling the AD Process for New Controllers.
Select I have read the previous information and understood consequences of the operation and click Next.
The Check Before Capacity Expansion page is displayed.
- The system automatically checks the expansion condition.
If any check item fails, rectify the faults and perform the check again.
After all check items are passed, click Next.
If the item The IBC public/private key pair is the default one is not passed, see How Can I Restore the IBC Public/Private Key Pair to the Default Value?
The Confirm the Networking Environment page is displayed.
- Confirm the network environment and configure data switches.
- Click the network diagram to obtain the network diagram.
It is recommended that you connect the cables according to the networking diagram in this document. Other networking may cause controller expansion failure.
- Ensure that cables are properly connected according to the network diagram.
Select I have read the previous information and understood consequences of the operation and click Next.
The Configure Data Switch page is displayed.
- Enter the configuration information about the data switch, as described in Table 11-12.
Table 11-12 Data switch parameters
Parameter
Description
Data switch 0 Management IP Address
IP address of the management network port on data switch 0.
Data switch 0 Username
User name used to log in to data switch 0 through SSH. For details about the user name, see Configuring New IP Addresses for the Management Network Ports on the Switches and SSH Login User Information.
Data switch 0 Password
Password used to log in to data switch 0 through SSH.
Data switch 0 SSH Port
Port used to log in to data switch 0 through SSH. The default port is port 22.
Data switch 1 Management IP Address
IP address of the management network port on data switch 1.
Data switch 1 Username
User name used to log in to data switch 1 through SSH. For details about the user name, see Configuring New IP Addresses for the Management Network Ports on the Switches and SSH Login User Information.
Data switch 1 Password
Password used to log in to data switch 1 through SSH.
Data switch 1 SSH Port
Port used to log in to data switch 1 through SSH. The default port is port 22.
- Before configuring the data switch, ensure that no other user has logged in or is using the switch. Otherwise, the configuration operation will fail.
- If you need to manually configure data switches, complete the configuration by referring to (Optional) Manually Configuring Switches (CE8850-32CQ-EI) and click Cancel.
After configuration, click OK.
The Scan for Node Information page is displayed.
- Click the network diagram to obtain the network diagram.
- The system automatically detects node information. If the system fails to detect the information of the new controllers, rectify the faults as prompted and click Rescan.
After the system obtains the node information, confirm and select the controller enclosure to be expanded based on Controller enclosure SN.
After confirming all controller enclosures, select I have read the previous information and understood consequences of the operation and click Next.
The Check the Added Controller page is displayed.
You can query the SN of a controller enclosure on the label on its exterior, for example, 2102XXXXXXXXE700000X.
- The system automatically performs a pre-expansion check.
If the check fails, identify and rectify the failed items. Then click Recheck to perform the check again.
After all check items are passed, click Next.
The Capacity Expansion page is displayed.
- The system automatically starts adding controllers.
A Danger dialog box will be displayed indicating that this operation will restore the new controllers to the default settings.
Confirm the information in the dialog box and select I have read and understood the consequence associated with performing this operation and click OK. The system continues to add controllers.
If either of the following issues occurs, refer to What Can I Do When an Exception Occurs in Using SmartKit to Add a New Controller Enclosure?
- If any expansion item fails and the system reports "The communication is abnormal or the system is busy", the connection between SmartKit and the storage system is interrupted.
- If any expansion item is paused unexpectedly, a fault occurs during the expansion. Rectify the fault according to the suggestions provided by SmartKit and then click Re-Execute. If the item is paused again, the fault still exists.
After the controllers are successfully added, click Next.
The Post-expansion Check page is displayed.
- The system automatically performs a post-expansion check.
If the check fails, identify and rectify the failed items. Then click Recheck to perform the check again.
After all check items are passed, click Next.
The Completed page is displayed.
- Click Finish to complete the expansion.
- Confirm the precautions of SmartKit.
- Inspect the system after expansion.
- Click Post-Expansion Inspection. The inspection tool page is displayed.
- Click Select Check Items.
In the check item list, select the items you want to check.
- Click Next to start the inspection.
- Open the result directory is linked to the directory that stores the inspection report.
- View the report is linked to the inspection results that are saved as .html files. These files are also compressed and stored in the result directory.
- Click Finish. The inspection is complete.
Expanding 6 to 10 Controllers
This section describes how to use SmartKit to add controllers.
Prerequisites
- C versions of the controller enclosures to be added for expansion and the original storage system are consistent. Otherwise, upgrade the controller software of the earlier version. For specific upgrade methods, refer to Upgrade Guide of the target version.
- The memory size of the controllers to be added for expansion is the same as that of the original storage system.
- Controller enclosures to be added have been powered on.
- The network has been deployed based on the scenario.
- There is no critical or major alarm in the storage system.
- The IP addresses of the management network ports on controller enclosures connected to the management network must be different. For details, see section "Changing IP Addresses of Management Network Ports" in the Installation Guide.
Precautions
- SmartKit is used to expand controllers for the storage system.
- The operation procedure varies with the SmartKit version. The actual GUI prevails.
- For controller enclosure 0, ensure that no Ethernet NICs are installed in slots IOM H9/L9 to IOM H13/L13. If Ethernet NICs have been installed in these slots, remove the Ethernet NICs before controller expansion and insert them back after controller expansion. Otherwise, the Ethernet NICs cannot be used after controller expansion.
Procedure
- Open SmartKit.
- Add the storage device whose capacity is to be expanded to SmartKit.
- In the main window of SmartKit, click the Devices tab and select Add.
The dialog box for adding devices is displayed.
- In Basic Information, select Specify IP Address (add a device by the IP address) and enter the management IP address of the original storage system. Then click Next.
- In the Login Information area, enter the user name and password of the storage system super administrator and click Finish.
- When a device is added for the first time or a device certificate is not trusted, a message is displayed indicating that the connection is not trusted.
- When an SSH server is added for the first time or the fingerprint of an SSH server changes, a message is displayed asking whether you want to continue to register the SSH server.
- In the main window of SmartKit, click the Devices tab and select Add.
- In the main window of SmartKit, choose Home > Storage > Capacity Expansion > Add Controllers.
The Add Controllers page is displayed.
- Select devices.
- Click Device Selection. The Select Devices dialog box is displayed.
- Select the storage system for which you want to expand controllers and the results save folder and click OK.
- Ensure compliance with the safety operation guide.
- Click Safety Operation Guide. The Safety Operation Guide dialog box is displayed.
- Make sure that the prerequisites displayed on the user interface have been prepared. Select the prerequisites and click OK.
- Evaluate the capacity expansion solution.
- Click Expansion Evaluation.
The Expansion Configuration page is displayed.
- (Optional) For devices that are configured with HyperMetro, select the device you want to perform capacity expansion evaluation from the device list and click Next.
- Select a capacity expansion scenario.
Select Add controllers in Capacity expansion scenario. Select the number of controllers after the capacity expansion, and enter the BOM codes of the new enclosure by referring to the BOQ for capacity expansion. Use commas (,) to separate multiple BOM codes.
- Click Add Hardware Information and Expansion Mode.
You can add multiple configuration policies.
- Specify the configuration parameters according to the capacity expansion plan. Table 11-13 lists the parameters.
Table 11-13 Capacity evaluation parameters
Parameter
Description
Storage Capacity Expansion Mode
Method to add storage space.
BOM of Disk
BOM code of the new disk.
NOTE:- If the BOM code of the new disk is the same as an existing one in the storage system, select the BOM code from the drop-down list.
- If the BOM code of the new disk is not included in the drop-down list box, select Customize.
- To add multiple disk types, click Add Hardware Information and Expansion Mode to add new configuration policies.
Disk Type
Type of the new disks.
NOTE:- When Customize is selected for BOM of Disk, you need to manually select a disk type.
- Self-encrypting drives (SEDs) are supported.
Physical Capacity of a Single Disk
Capacity of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually enter the disk capacity.
Capacity Unit
Capacity unit of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually select a capacity unit.
Disk Quantity
Number of new disks.
Operation
You can click Delete to delete the current configuration policy.
- Click Next.
The Information page is displayed.
- Read and confirm the displayed message, and click OK.
The Start Evaluation page is displayed and the system starts evaluating the capacity expansion solution.
- After the evaluation is complete, click Open the report to go to the save path of the evaluation report. The report is a .zip file named by the evaluation time.
- You can also click View the report to open the report directly.
- Click Finish.
Rectify the failed items (if any) according to the suggestions and evaluate the solution again. If the items fail again, contact Huawei technical support engineers for assistance. Otherwise, risks may arise during capacity expansion.
- Click Expansion Evaluation.
- Open the Add Controller Wizard dialog box.
- Click Expansion.
The Expansion page is displayed.
- Select Add Controller.
The Select Expansion Mode dialog box is displayed.
- Select Networking Mode and Configuration after expansion.
Set Networking Mode to Switch-based network and Configuration to the number of controllers after expansion.
- Click OK.
The Add Controller Wizard dialog box is displayed.
- Click Expansion.
- Add controllers as prompted by the wizard.
- Confirm the precautions of SmartKit.
- If the expansion engine has been unpacked before or has been powered on before, perform operations in Clearing Configuration Information About Controllers to Be Added.
- Ensure that the AD process has been enabled. For details, see Enabling the AD Process for New Controllers.
Select I have read the previous precautions, completed the related operations, and understood consequences of the operation and click Next.
The Confirm Specifications of Controllers Being Added page is displayed.
- Confirm the expansion-related specifications.
This step applies only to the scenario six controllers are expanded to ten controllers, and the 4 U controller enclosure to be added contains four controllers. Otherwise, skip this step, select precautions, and click Next.
If the environment has four controllers in a 4 U controller enclosure, follow instructions in Restoring Dual-controller configuration for processing.
After confirmation, select I have confirmed the information and understood the consequences associated with performing this operation and click Next.
The Check Before Capacity Expansion page is displayed.
- The system automatically checks the expansion condition.
If any check item fails, rectify the faults and perform the check again.
After all check items are passed, click Next.
If the item The IBC public/private key pair is the default one is not passed, see How Can I Restore the IBC Public/Private Key Pair to the Default Value?
The Complete Networking page is displayed.
- The system automatically modifies the expansion configuration.
A dialog box is displayed when the system automatically adds controllers. Install controllers by referring to How Do I Install New Controllers in a Controller Enclosure?. Confirm the information in the dialog box, select I have confirmed the preceding information and inserted the controllers to be added, and click OK. The system continues to add controllers.
If any expansion item is paused unexpectedly, a fault occurs during the expansion. Rectify the fault according to the suggestions provided by SmartKit and then click Re-Execute. If the item is paused again, the fault still exists. In this situation, refer to What Can I Do When SmartKit Pauses Unexpectedly in Adding Controllers to a 4 U Controller Enclosure?
After modification, click Next.
The Post-expansion Check page is displayed.
- The system automatically performs a post-expansion check.
If the check fails, rectify the faults and click Recheck to perform the check again.
After all check items are passed, click Next.
The Obtain Cluster Information page is displayed.
- The system automatically obtains the cluster information.
After the cluster information has been obtained, click Next.
The Confirm the Networking Environment page is displayed.
- Click the network diagram to obtain the network diagram.
It is recommended that you connect the cables according to the networking diagram in this document. Other networking may cause controller expansion failure.
Ensure that cables are properly connected according to the network diagram.
Select I have read the previous information and understood consequences of the operation and click Next.
The Scan for Node Information page is displayed.
- The system automatically detects node information. If the system fails to detect the information of the new controllers, rectify the faults as prompted and click Rescan.
After the system obtains the node information, confirm and select the controller enclosure to be expanded based on Controller enclosure SN.
After confirming all controller enclosures, select I have read the previous information and understood consequences of the operation and click Next.
The Check the Added Controller page is displayed.
You can query the SN of a controller enclosure on the label on its exterior, for example, 2102XXXXXXXXE700000X.
- The system automatically checks the network connection.
If the network connection check fails, reconnect the network and click Recheck.
After the check passes, click Next.
The Capacity Expansion page is displayed.
- The system automatically starts adding controllers.
If either of the following issues occurs, refer to What Can I Do When an Exception Occurs in Using SmartKit to Add a New Controller Enclosure?
- If any expansion item fails and the system reports "The communication is abnormal or the system is busy", the connection between SmartKit and the storage system is interrupted.
- If any expansion item is paused unexpectedly, a fault occurs during the expansion. Rectify the fault according to the suggestions provided by SmartKit and then click Re-Execute. If the item is paused again, the fault still exists.
After the controllers are successfully added, click Next.
The Post-expansion Check page is displayed.
- The system automatically performs a post-expansion check.
If the check fails, identify and rectify the failed items. Then click Recheck to perform the check again.
After all check items are passed, click Next.
The Completed page is displayed.
- Click Finish to complete the expansion.
- Confirm the precautions of SmartKit.
- Inspect the system after expansion.
- Click Post-Expansion Inspection. The inspection tool page is displayed.
- Click Select Check Items.
In the check item list, select the items you want to check.
- Click Next to start the inspection.
- Open the result directory is linked to the directory that stores the inspection report.
- View the report is linked to the inspection results that are saved as .html files. These files are also compressed and stored in the result directory.
- Click Finish. The inspection is complete.
Expanding 8 Controllers to 10 or More Controllers
This section describes how to use SmartKit to add controllers.
Prerequisites
- C versions of the controller enclosures to be added for expansion and the original storage system are consistent. Otherwise, upgrade the controller software of the earlier version. For specific upgrade methods, refer to Upgrade Guide of the target version.
- The memory size of the controllers to be added for expansion is the same as that of the original storage system.
- Controller enclosures to be added have been powered on.
- The network has been deployed based on the scenario.
- There is no critical or major alarm in the storage system.
- The IP addresses of the management network ports on controller enclosures connected to the management network must be different. For details, see section "Changing IP Addresses of Management Network Ports" in the Installation Guide.
Precautions
- SmartKit is used to expand controllers for the storage system.
- The operation procedure varies with the SmartKit version. The actual GUI prevails.
Procedure
- Open SmartKit.
- Add the storage device whose capacity is to be expanded to SmartKit.
- In the main window of SmartKit, click the Devices tab and select Add.
The dialog box for adding devices is displayed.
- In Basic Information, select Specify IP Address (add a device by the IP address) and enter the management IP address of the original storage system. Then click Next.
- In the Login Information area, enter the user name and password of the storage system super administrator and click Finish.
- When a device is added for the first time or a device certificate is not trusted, a message is displayed indicating that the connection is not trusted.
- When an SSH server is added for the first time or the fingerprint of an SSH server changes, a message is displayed asking whether you want to continue to register the SSH server.
- In the main window of SmartKit, click the Devices tab and select Add.
- In the main window of SmartKit, choose Home > Capacity Expansion > Add Controllers.
The Add Controllers page is displayed.
- Select devices.
- Click Device Selection. The Select Devices dialog box is displayed.
- Select the storage system for which you want to expand controllers and the results save folder and click OK.
- Ensure compliance with the safety operation guide.
- Click Safety Operation Guide. The Safety Operation Guide dialog box is displayed.
- Make sure that the prerequisites displayed on the user interface have been prepared. Select the prerequisites and click Confirm.
- Evaluate the capacity expansion solution.
- Click Expansion Evaluation.
The Expansion Configuration page is displayed.
- (Optional) For devices that are configured with HyperMetro, select the device you want to perform capacity expansion evaluation from the device list and click Next.
- Select a capacity expansion scenario.
Select Add controllers in Capacity expansion scenario. Select the number of controllers after the capacity expansion, and enter the BOM codes of the new enclosure by referring to the BOQ for capacity expansion. Use commas (,) to separate multiple BOM codes.
- Click Add Hardware Information and Expansion Mode.
You can add multiple configuration policies.
- Specify the configuration parameters according to the capacity expansion plan. Table 11-14 lists the parameters.
Table 11-14 Capacity evaluation parameters
Parameter
Description
Storage Capacity Expansion Mode
Method to add storage space.
BOM of Disk
BOM code of the new disk.
NOTE:- If the BOM code of the new disk is the same as an existing one in the storage system, select the BOM code from the drop-down list.
- If the BOM code of the new disk is not included in the drop-down list box, select Customize.
- To add multiple disk types, click Add Hardware Information and Expansion Mode to add new configuration policies.
Disk Type
Type of the new disks.
NOTE:- When Customize is selected for BOM of Disk, you need to manually select a disk type.
- Self-encrypting drives (SEDs) are supported.
Physical Capacity of a Single Disk
Capacity of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually enter the disk capacity.
Capacity Unit
Capacity unit of the new disks.
NOTE:When Customize is selected for BOM of Disk, you need to manually select a capacity unit.
Disk Quantity
Number of new disks.
Operation
You can click Delete to delete the current configuration policy.
- Click Next.
The Information page is displayed.
- Read and confirm the displayed message, and click OK.
The Start Evaluation page is displayed and the system starts evaluating the capacity expansion solution.
- After the evaluation is complete, click Open the report to go to the save path of the evaluation report. The report is a .zip file named by the evaluation time.
- You can also click View the report to open the report directly.
- Click Finish.
Rectify the failed items (if any) according to the suggestions and evaluate the solution again. If the items fail again, contact Huawei technical support engineers for assistance. Otherwise, risks may arise during capacity expansion.
- Click Expansion Evaluation.
- Open the Add Controller Wizard dialog box.
- Click Expansion.
The Expansion page is displayed.
- Select Add Controller.
The Select Expansion Mode dialog box is displayed.
- Select Networking Mode and Configuration after expansion.
Set Networking Mode to Switch-based network and Configuration to the number of controllers after expansion.
- Click OK.
The Add Controller Wizard dialog box is displayed.
- Click Expansion.
- Add controllers as prompted by the wizard.
- Confirm the precautions of SmartKit.
- If the expansion engine has been unpacked before or has been powered on before, perform operations in Clearing Configuration Information About Controllers to Be Added.
- Ensure that the AD process has been enabled. For details, see Enabling the AD Process for New Controllers.
Select I have read the previous information and understood consequences of the operation and click Next.
The Check Before Capacity Expansion page is displayed.
- The system automatically checks the expansion condition.
If any check item fails, rectify the faults and perform the check again.
After all check items are passed, click Next.
If the item The IBC public/private key pair is the default one is not passed, see How Can I Restore the IBC Public/Private Key Pair to the Default Value?
The Confirm the Networking Environment page is displayed.
- Click the network diagram to obtain the network diagram.
It is recommended that you connect the cables according to the networking diagram in this document. Other networking may cause controller expansion failure.
Ensure that cables are properly connected according to the network diagram.
Select I have read the previous information and understood consequences of the operation and click Next.
The Scan for Node Information page is displayed.
- The system automatically detects node information. If the system fails to detect the information of the new controllers, rectify the faults as prompted and click Rescan.
After the system obtains the node information, confirm and select the controller enclosure to be expanded based on Controller enclosure SN.
After confirming all controller enclosures, select I have read the previous information and understood consequences of the operation and click Next.
The Check the Added Controller page is displayed.
You can query the SN of a controller enclosure on the label on its exterior, for example, 2102XXXXXXXXE700000X.
- The system automatically performs a pre-expansion check.
If the check fails, identify and rectify the failed items. Then click Recheck to perform the check again.
After all check items are passed, click Next.
The Capacity Expansion page is displayed.
- The system automatically starts adding controllers.
A Danger dialog box will be displayed indicating that this operation will restore the new controllers to the default settings.
Confirm the information in the dialog box and select I have read and understood the consequence associated with performing this operation and click OK. The system continues to add controllers.
If either of the following issues occurs, refer to What Can I Do When an Exception Occurs in Using SmartKit to Add a New Controller Enclosure?
- If any expansion item fails and the system reports "The communication is abnormal or the system is busy", the connection between SmartKit and the storage system is interrupted.
- If any expansion item is paused unexpectedly, a fault occurs during the expansion. Rectify the fault according to the suggestions provided by SmartKit and then click Re-Execute. If the item is paused again, the fault still exists.
After the controllers are successfully added, click Next.
The Post-expansion Check page is displayed.
- The system automatically performs a post-expansion check.
If the check fails, identify and rectify the failed items. Then click Recheck to perform the check again.
After all check items are passed, click Next.
The Completed page is displayed.
- Click Finish to complete the expansion.
- Confirm the precautions of SmartKit.
- Inspect the system after expansion.
- Click Post-Expansion Inspection. The inspection tool page is displayed.
- Click Select Check Items.
In the check item list, select the items you want to check.
- Click Next to start the inspection.
- Open the result directory is linked to the directory that stores the inspection report.
- View the report is linked to the inspection results that are saved as .html files. These files are also compressed and stored in the result directory.