Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Note: Even the most advanced machine translation cannot match the quality of professional translators.
Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Expansion Rollback
If controllers fail to be expanded, restore the storage system to factory settings and expand the controllers again.
Symptom
SmartKit may fail to expand controllers because:
- The configuration information about controller enclosure (enclosure SN: %s) fails to be modified.
- The BMC information about controller enclosure (enclosure SN: %s) fails to be synchronized.
- Controller expansion fails to be performed.
- The new controller enclosure (enclosure SN: %s) fails to be added to the cluster.
%s indicates the SN of the enclosure.
- When handling controller expansion failure, remove cables of storage systems that have not been added to the cluster to isolate controllers.
- If New engine (enclosure SN: %s) failed to be added to the cluster is displayed in SmartKit, the controller expansion cannot be rolled back. Contact Huawei technical support.
- For details about how to use the commands mentioned in this chapter, see Advanced O&M Command Reference of the corresponding product model.
- Do not restart the controllers to minimize the impact on cluster services.
Fault Diagnosis
Figure 10-14 Process of handling controller expansion failure
![]()