Example for Configuring One-way Frame Delay Measurement in a VLAN
Networking Requirements
As networks continue to rapidly develop and applications become more and more diversified, various value-added services such as IPTV, video conferencing and VOIP are becoming more widely used. Link connectivity and network performance determine QoS on bearer networks. Therefore, performance monitoring is important for service transmission.
As shown in Figure 11-9, CFM is configured between CEs. To provide high-quality video services, carriers need to monitor the one-way delay over mobile bearer links in real time, while monitoring link connectivity. Monitoring the one-way delay over mobile bearer links allows the carriers to respond quickly to video service quality deterioration.
Configuration Roadmap
Configure on-demand one-way frame delay measurement for the end-to-end link between the CEs to periodically collect statistics about the delay in frame transmission.
Procedure
- Configure VLANs.
# Configure CE1.
<Quidway> system-view [Quidway] sysname CE1 [CE1] vlan 2 [CE1-vlan2] quit [CE1] interface gigabitethernet 1/0/1 [CE1-GigabitEthernet1/0/1] port link-type trunk [CE1-GigabitEthernet1/0/1] port trunk allow-pass vlan 2 [CE1-GigabitEthernet1/0/1] quit
# Configure CE2.
<Quidway> system-view [Quidway] sysname CE2 [CE2] vlan 2 [CE2-vlan2] quit [CE2] interface gigabitethernet 1/0/1 [CE2-GigabitEthernet1/0/1] port link-type trunk [CE2-GigabitEthernet1/0/1] port trunk allow-pass vlan 2 [CE2-GigabitEthernet1/0/1] quit
# Configure PE1.
<Quidway> system-view [Quidway] sysname PE1 [PE1] vlan 2 [PE1-vlan2] quit [PE1] interface gigabitethernet 1/0/1 [PE1-GigabitEthernet1/0/1] port link-type trunk [PE1-GigabitEthernet1/0/1] port trunk allow-pass vlan 2 [PE1-GigabitEthernet1/0/1] quit [PE1] interface gigabitethernet 1/0/2 [PE1-GigabitEthernet1/0/2] port link-type trunk [PE1-GigabitEthernet1/0/2] port trunk allow-pass vlan 2 [PE1-GigabitEthernet1/0/2] quit
# Configure PE2.
<Quidway> system-view [Quidway] sysname PE2 [PE2] vlan 2 [PE2-vlan2] quit [PE2] interface gigabitethernet 1/0/1 [PE2-GigabitEthernet1/0/1] port link-type trunk [PE2-GigabitEthernet1/0/1] port trunk allow-pass vlan 2 [PE2-GigabitEthernet1/0/1] quit [PE2] interface gigabitethernet 1/0/2 [PE2-GigabitEthernet1/0/2] port link-type trunk [PE2-GigabitEthernet1/0/2] port trunk allow-pass vlan 2 [PE2-GigabitEthernet1/0/2] quit
- Configure basic Ethernet CFM functions and specify the MEP type as outward.
Configure basic Ethernet CFM functions on each CE. Create an MD named md3 and an MA named ma3, and bind the MA to the VLAN.
# Configure CE1.
[CE1] cfm enable [CE1] cfm md md3 [CE1-md-md3] ma ma3 [CE1-md-md3-ma-ma3] map vlan 2 [CE1-md-md3-ma-ma3] mep mep-id 3 interface gigabitethernet 1/0/1 outward [CE1-md-md3-ma-ma3] mep ccm-send mep-id 3 enable [CE1-md-md3-ma-ma3] remote-mep mep-id 4 [CE1-md-md3-ma-ma3] remote-mep ccm-receive mep-id 4 enable [CE1-md-md3-ma-ma3] quit [CE1-md-md3] quit
# Configure CE2.
[CE2] cfm enable [CE2] cfm md md3 [CE2-md-md3] ma ma3 [CE2-md-md3-ma-ma3] map vlan 2 [CE2-md-md3-ma-ma3] mep mep-id 4 interface gigabitethernet 1/0/1 outward [CE2-md-md3-ma-ma3] mep ccm-send mep-id 4 enable [CE2-md-md3-ma-ma3] remote-mep mep-id 3 [CE2-md-md3-ma-ma3] remote-mep ccm-receive mep-id 3 enable [CE2-md-md3-ma-ma3] quit [CE2-md-md3] quit
- Verify the CFM configuration.
# Run the display cfm remote-mep command on CE1 and CE2. You can view MEP information.
[CE1] display cfm remote-mep The total number of RMEPs is : 1 The status of RMEPs : 1 up, 0 down, 0 disable -------------------------------------------------- MD Name : md3 Level : 0 MA Name : ma3 RMEP ID : 4 VLAN ID : 2 VSI Name : -- L2VC ID : -- MAC : 4c1f-cc6b-c208 CCM Receive : enabled Trigger-If-Down : disabled CFM Status : up Alarm Status : none Interface TLV : -- Connect Status : up
[CE2] display cfm remote-mep The total number of RMEPs is : 1 The status of RMEPs : 1 up, 0 down, 0 disable -------------------------------------------------- MD Name : md3 Level : 0 MA Name : ma3 RMEP ID : 3 VLAN ID : 2 VSI Name : -- L2VC ID : -- MAC : 0044-0141-5410 CCM Receive : enabled Trigger-If-Down : disabled CFM Status : up Alarm Status : none Interface TLV : -- Connect Status : up
- Configure CE2 to receive DM frames.
# Configure CE2.
[CE2] cfm md md3 [CE2-md-md3] ma ma3 [CE2-md-md3-ma-ma3] delay-measure one-way receive mep 4 [CE2-md-md3-ma-ma3] quit [CE2-md-md3] quit
- Enable one-way frame delay measurement.
# Configure CE1.
[CE1] cfm md md3 [CE1-md-md3] ma ma3 [CE1-md-md3-ma-ma3] delay-measure one-way send mep 3 remote-mep 4 interval 1000 count 20 [CE1-md-md3-ma-ma3] quit [CE1-md-md3] quit
- Verify the configuration.
# After the configuration is complete, run the display y1731 statistic-type oneway-delay md md3 ma ma3 command on CE2. You can see statistics about the one-way frame delay.
[CE2] display y1731 statistic-type oneway-delay md md3 ma ma3 Measurement Start Time : 2014-11-01 15:41:27 Latest one-way delay statistics: -------------------------------------------------------------------------------- Index Delay(usec) Delay variation(usec) -------------------------------------------------------------------------------- 1 10000 - 2 10000 0 3 10000 0 4 10000 0 5 10000 0 6 10000 0 7 10000 0 8 10000 0 9 10000 0 10 10000 0 11 10000 0 12 40000 30000 13 10000 30000 14 10000 0 15 10000 0 16 10000 0 17 10000 0 18 10000 0 19 10000 0 20 10000 0 -------------------------------------------------------------------------------- Average delay(usec) : 11764 Average delay variation(usec) : 3750 Maximum delay(usec) : 40000 Maximum delay variation(usec) : 30000 Minimum delay(usec) : 10000 Minimum delay variation(usec) : 0
Configuration Files
CE1 configuration file
# sysname CE1 # vlan batch 2 # cfm enable # interface GigabitEthernet1/0/1 port link-type trunk port trunk allow-pass vlan 2 # cfm md md3 ma ma3 map vlan 2 mep mep-id 3 interface GigabitEthernet1/0/1 outward mep ccm-send mep-id 3 enable remote-mep mep-id 4 remote-mep ccm-receive mep-id 4 enable # return
CE2 configuration file
# sysname CE2 # vlan batch 2 # cfm enable # interface GigabitEthernet1/0/1 port link-type trunk port trunk allow-pass vlan 2 # cfm md md3 ma ma3 map vlan 2 mep mep-id 4 interface GigabitEthernet1/0/1 outward mep ccm-send mep-id 4 enable remote-mep mep-id 3 remote-mep ccm-receive mep-id 3 enable delay-measure one-way receive mep 4 # return
PE1 configuration file
# sysname PE1 # vlan batch 2 # interface GigabitEthernet1/0/1 port link-type trunk port trunk allow-pass vlan 2 # interface GigabitEthernet1/0/2 port link-type trunk port trunk allow-pass vlan 2 # return
PE2 configuration file