Licensing Requirements and Limitations for CFM
Involved Network Elements
Other network elements are required to support CFM functions.
Licensing Requirements
CFM is a basic feature of a switch and is not under license control.
Feature Support in V200R019C10
All models of S9300 and S9300X series switches support CFM.
FC and SC series cards do not support CFM.
Feature Limitations
When the MPU is equipped with LE0MFSUA or the MPU is LH2D2SRUDC00, LE2D2SRUDC01, or LST3MPUE0000, it is applicable to the scenario where one MEP is configured at the local end and multiple RMEPs are configured at the remote end.
If the MPU is equipped with LE0MFSUA or the MPU is LH2D2SRUDC00 or LE2D2SRUDC01, when multiple MEPs are configured in a VLAN, the EOAM1AG_1.3.6.1.4.1.2011.5.25.136.1.6.36 hwDot1agCfmUnexpectedMEP alarm cannot be correctly reported. It is recommended that multiple MEPs be configured in different VLANs to implement this function.