NQA
NQA/4/FALLING_ALARM
Message
NQA/4/FALLING_ALARM:The [alarm-node] defined in nqa alarm table(OwnerIndex = [OCTET] TestName = [OCTET] AlarmEntryNumber = [INTEGER])has alarm value [alarm-value],less than threshold [threshold]. It's alarm sample type is [alarm-sample-type].
Parameters
Parameter Name | Parameter Meaning |
---|---|
[alarm-node] | Indicates the node that generates the alarm. |
OwnerIndex | Indicates the administrator of the NQA test instance. |
TestName | Indicates the name of the NQA test instance. |
AlarmEntryNumber | Indicates the index of the alarm table. |
[alarm-value] | Indicates the value of the node that generates the alarm. |
[threshold] | Indicates the user-defined lower limit. |
[alarm-sample-type] | Indicates the type of the sampled alarm. |
Procedure
- Run the display nqa-agent command and check alarm entry-number jitter-average absolute falling-threshold to see the threshold value is proper.
- If the lower limit is too large, run the alarm command to set the lower limit to be a proper value, and then go to 3.
- If the lower limit is proper, go to 2.
- If the alarm is generated because of a network problem, check the configurations and services of the network, and contact technical support personnel.
- End.
NQA/4/RISING_ALARM
Message
NQA/4/RISING_ALARM:The [alarm-node] defined in nqa alarm table(OwnerIndex=[OCTET] TestName=[OCTET] AlarmEntryNumber=[INTEGER])has alarm value [alarm-value],going out of threshold [threshold].It's alarm sample type is [alarm-sample-type].
Parameters
Parameter Name | Parameter Meaning |
---|---|
[alarm-node] | Indicates the node that generates the alarm. |
OwnerIndex | Indicates the administrator of the NQA test instance. |
TestName | Indicates the name of the NQA test instance. |
AlarmEntryNumber | Indicates the index of the alarm table. |
[alarm-value] | Indicates the value of the node that generates the alarm. |
[threshold] | Indicates the user-defined upper limit. |
[alarm-sample-type] | Indicates the type of the sampled alarm. |
Procedure
- Run the display nqa-agent command and check alarm entry-number jitter-average absolute rising-threshold to see whether the threshold value is proper.
- If the upper limit is too small, run the alarm command to set the upper limit to be a proper value, and then go to 3.
- If the upper limit is proper, go to 2.
- If the alarm is generated because of a network problem, check the configurations and services of the network, and contact technical support personnel.
- End.
NQA/4/UPLOAD_FILE
Message